810276
13
Zoom out
Zoom in
Previous page
1/28
Next page
13
o p e r at i n g i n s t r u c t i o n s
English
7. Time Schedule
The temperature is controlled according to the time
schedule, see section 8.3 ‘Setting Time Schedule’.
The appliance is fully automatically ignited and
switched off.
7.1 Temporarily changing the temperature
set point
The temperature set point of a time schedule pe-
riod can temporarily be enhanced or lowered.
Press the or key once to set the temporarily
required set point. The display shown in gure 11 ap-
pears.
The currently set temperature flashes.
Set the temporarily required temperature set point by pressing the and
keys. Depending on which key is pressed, the or symbol will be momenta-
rily visible on the display.
Wait a few seconds or press the key to leave the menu.
The display (example) shown in figure 12 appears. The symbol indicates
that the temperature set point has been adjusted manually.
The temporary adjustment can be undone by setting the manually adjusted
set point back to the set point of the current time period. In case of a transiti-
on to a new time period, the temporary adjustment is cancelled automatically.
7.2 Temporarily interrupting the time schedule
In case of the use of a time schedule, the appliance
can also be switched off temporarily.
Press the key once if the appliance has been igni-
ted.
The display (example) shown in figure 13 appears.
The symbol flashes to indicate that the appli-
ance is being switched off.
After the appliance is switched off, the display
shown in figure 14 appears.
The symbol flashes to indicate that the
appliance has to be ignited manually by
pressing the and keys simultaneously.
When the appliance is ignited again, the time sche-
dule becomes active again.
!Caution
The temperature set point can not be changed when the time schedule is tempo-
rarily interrupted.
13
14
11
12
EN
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Metro 150XT Tunnel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Metro 150XT Tunnel in the language / languages: English as an attachment in your email.

The manual is 4.24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Metro 150XT Tunnel

DRU Metro 150XT Tunnel User Manual - German - 28 pages

DRU Metro 150XT Tunnel User Manual - Dutch - 28 pages

DRU Metro 150XT Tunnel User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info