7.3.3 Wall terminal (C11)When using a wall terminal (C11), the following applies:The construction of the chosen system has to be allowed.1Check that the vertical pipe length falls between the minimum and maximum lengths (see table 7-5).1Check that the horizontal pipe length (wall terminal excluded) falls within the minimum and maximum length (see table 7-5).2In the horizontal section, 1 bend of 90° may be included. This bend counts for 2 metres. This means that the maximum allowed length is reduced by 2 metres. A 45° bend counts for 1 metre.1Determine the correct adjustment of the appliance (see table 7-5).1Adjust the appliance correctly with, for instance, a restrictor slide and an air inlet guide (see section 8.2).The rosette of the wall terminal is too small to seal the opening in case of passage through combustible material. That is why a heat-resistant intermediate plate of sufficient size should first be mounted to the wall. Then, the rosette is mounted on the intermediate sheet.3When using a wall terminal, place the terminal with a downward slope of 1 cm / metre towards the outside, in order to prevent rain water from raining in.Installation manual30
0 - 3m
0.5 - 0.8m
38C-744ZT
1x90°
0
0
38C-744W
1x90°
Table 7-5aTable 7-5bSettingAir inlet guideRestrictor slideFlue gas distribution plateApplyxxx- Only use a 200/130 mm concentric system, including wall terminal.- In the case of this configuration, an unpainted stainless steel wall terminal must be used.- Factory setting: flue gas distribution plate mounted, the air inlet guides and restrictor slide are supplied separately.- Only use a 200/130 mm concentric system, including wall terminal.- Factory setting: flue gas distribution plate mounted, the air inlet guides and restrictor slide are supplied separately.SettingAir inlet guideRestrictor slideFlue gas distribution plateApplyxxx
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for DRU Maestro 80-3 RCH at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of DRU Maestro 80-3 RCH in the language / languages: English as an attachment in your email.
The manual is 7.09 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.