Installation manual177.3 Concentric system7.3.1 GeneralThe appliance is connected to a flue gas discharge / combustion air supply system delivered by DRU, hereafter referred to as the concentric system. DRU has different concentric systems in its range.In the case of a concentric system, the inner tube is used as flue gas discharge. The combustion air is supplied by the outer tube. As a result, the latter always has a relatively low temperature. For the maximum temperature of the outer tube, see the technical data in table 4-1. The concentric system has been tested in combination with the appliance. Other concentric systems are not permitted.See the table below for the different concentric systems of DRU and their application:SystemDRU LAS AG-I 150/100DRU LAS ES-I 150/100DRU LAS ES-I 200/130DRU LAS ES-E 200/150/100DRU PV-I 100/60Permittedfor thisappliance.NoYesYesYesYesRemarksAlu-galva tubes for use inside the building*.Diameter Ø150/100 mm.Cannot be combined with the SS systems.SS tubes for use inside the building*.Diameter Ø150/100 mm.Using an SS adapter, it is possible to construct further with theinsulated LAS ES-E 200/150/100 system.SS tubes for use inside the building*.Diameter Ø 200/130.Using an SS adapter, if permitted, it is possible to construct further with LAS-ES-I 150/100.Insulated SS tubes.Discharge diameter Ø150/100.External diameter Ø 200 mm.Intended for use inside or outside building for placement in, for example, timber frame construction, execute with 0 mm distance along combustible material etc. It is not possible to continue building with an SS adapter with LAS ES-I 150/100.Optional discharge system with fan for discharge up to approx. 60 metres long.* With the exception of the components intended for that purpose, such as roof and wall terminals.The diameter of the concentric system appliance connection can be found in table 4-1. By means of natural draft, the flue gases are discharged to the outside, this can be achieved by means of a wall terminal (C11) or a roof terminal (C31). If necessary, an existing chimney can be used (C91, see section 7.3.5).In addition, if combined with PowerVent® (C12, C32), it is possible in many cases to discharge the flue gases with a smaller diameter (DRU PV-I 100/60).1Only use the concentric system supplied by DRU This system has been tested in combination with the appliance. DRU cannot guarantee a proper and safe operation of other systems and does not accept any responsibility or liability for this.1Use a chimney kit for making a connection to the chimney; this can be supplied by DRU.1For terminals, observe the information in table 7-2.Table 7-1: Concentric systems and their application
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Maestro 75 RCH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Maestro 75 RCH in the language / languages: English as an attachment in your email.

The manual is 5.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Maestro 75 RCH

DRU Maestro 75 RCH User Manual - German - 28 pages

DRU Maestro 75 RCH User Manual - Dutch - 28 pages

DRU Maestro 75 RCH Installation Guide - Dutch - 40 pages

DRU Maestro 75 RCH User Manual - French - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info