571623
6
Zoom out
Zoom in
Previous page
1/44
Next page
English
INSTALLATION MANUAL
5. Installation
5.1 Type of gas
The data plate indicates for which type of gas, gas pressure and for which country this appliance is intended.
The data plate can be found on the appliance or can be attached to a chain to which it should remain attached.
!Caution
Check whether the appliance is suitable for the type of gas and gas pressure used at the location.
5.1.1 Reconstruction to different type of gas
In order to convert this appliance to a different type of gas, please contact DRU's service department and ask for
the possibilities.
5.2 Gas connection
Place a gas tap in the gas pipe in accordance with the applicable regulations.
The gas connection on the gas control is located next to the receiver (see Appendix 3, fig. 38 (G)).
!Caution
Make sure there is no dirt in the gas pipes and connections.
No soldering may take place at the flexible gas hose(s), as this could cause leaks.
The following requirements apply to the gas connection:
Use a gas pipe with the correct dimensions, so that no pressure loss can occur.
The gas tap must be approved (in the EU this will be the CE mark).
You should always be able to reach the gas tap.
5.3 Electric connection
In case of a 230 Volt electrical connection, provide proper grounding. Place this electrical connection away from
the appliance, as low as possible in the chimney breast. This has to do with the temperature development in the
chimney breast.
!Caution
Make sure that it is easy to disconnect the appliance from the power supply after installation;
by disconnecting the plug;
or by means of a 2-core switch installed by a recognised installer in accordance with current regulations.
!Caution
Protect the gas control and electric components, hereafter referred to as the gas control, against building
dust and moisture!
For connecting the receiver and control panel at an appliance equipped with the CM system ®, you must
observe the instructions in the supplied manual.
5.3.1 Connecting the switch contact (if applicable)
It is possible to operate one or more lamps (in case of several lamps, a maximum of 0.5A/250VAC/30VDC) via the
remote control of the appliance. You could think of the lamps of Dru's lux elements. For this, you can use switch
contact B on the receiver (see appendix 3, fig 36). The switch contact is not polar sensitive.
5.3.2 Connection extra power supply (max. 80W, 230VAC) (if applicable)
This connection is ideal for possible lighting or a ventilation system in the chimney breast and can be operated by
means of the remote control (see appendix 3, fig. 36 (C)). The power supply of this connection is identical to the
mains voltage and it can be subjected to a maximum load of 80 Watts.
5.4 Placing the appliance
!Caution
Place the appliance in front of a heat-resistant and non combustible wall. The wall brackets on a built-in
appliance ensure that the minimum distance to the wall is maintained.
Ensure there are no combustible objects or materials present in the fire's radiation range, within a distance of
500 mm, unless indicated otherwise.
Place the concentric system in such a way that no fire hazard is ever created (also see section 5.8).
Take sufficient measures to prevent temperature of a wall behind the chimney breast becoming too high,
including the materials and/or objects behind the wall.
Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material.
Make sure that the appliance to be installed has a stable position. Fasten possible extending legs with the
self-tapping screws.
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Lugo 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Lugo 70 in the language / languages: English as an attachment in your email.

The manual is 4.96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Lugo 70

DRU Lugo 70 User Manual - English - 28 pages

DRU Lugo 70 User Manual - German - 28 pages

DRU Lugo 70 Installation Guide - German - 44 pages

DRU Lugo 70 User Manual - Dutch - 28 pages

DRU Lugo 70 Installation Guide - Dutch - 44 pages

DRU Lugo 70 User Manual - French - 28 pages

DRU Lugo 70 Installation Guide - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info