528137
40
Zoom out
Zoom in
Previous page
1/60
Next page
38
INSTALLATION MANUAL
POSSIBLE CAUSE
3. Bent pins of the 8-wire connector.
4. Damaged magnetic valve.
5. Thermocouple 2 still too hot.
1. Air in the pilot burner pipe.
2. Wires of thermocouple 1 have been
cross-connected.
3. No spark at the pilot burner.
4. Injector is blocked up.
1. Receiver is damaged.
1. Thermocouple 1 does not function.
2. Batteries (almost) empty.
PROBLEM
E. No pilot burner fl ame
F. Electronics keep sparking while
the pilot burner is ignited
G. Pilot burner is burning, but
magnetic valve closes after ca.
10 seconds or when the appli-
ance gets hot
REMEDY
3. Make sure that the pins of the
8-wire connector are straight.
4. Replace the gas control.
5. Wait until the thermocouple has
cooled down suffi ciently
1. Flush the pipe or start the ignition
process several times.
2. Check the polarity of the thermo-
couple wiring.
Connect the thermocouple wiring
properly, if necessary.
3.1 Check if the ignition cable (S) is
lying free from metal parts;
see fi g. 16.
If necessary, move it away from the
metal parts.
3.2 If necessary, replace the ignition
cable.
3.3 If necessary, replace the ignition
pen.
4.1 Clean the injector.
4.2 If necessary, replace the injector.
1. Replace the receiver and confi rm
the code (remedy 1 at A)
1.1 Measure the voltage, using a digital
multimeter, set to mV range, by
connecting the cables to the cable
shoe. The cable shoe is located on
the outside, directly next to the
magnet nut at the rear of the gas
control; see fi g. 21.
The voltage should be at least
5mV within 20 seconds.
It may not be lower when the ap-
pliance is warm.
If the voltage is too low:
- the thermocouple should be
placed better in the fl ame or
- the thermocouple should be
replaced.
1.2 Check the size of the pilot burner
ame.
Correct a fl ame that is too small.
1.3 Check the wiring of the thermo-
couple to the receiver.
If necessary, replace the wiring.
2. Replace the receiver’s batteries.
!Caution
Avoid short circuit between the
batteries and metal parts of the
appliance.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 70 in the language / languages: English, Dutch as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 70

DRU GLOBAL 70 User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info