528137
30
Zoom out
Zoom in
Previous page
1/60
Next page
28
INSTALLATION MANUAL
6.3 Gas connection
Place a gas tap in the gas connection, close to the appliance.
- Make sure there is no dirt in gas pipes and
connections;
- Prevent twisting the gas tap when con-
necting the gas pipe.
The following requirements apply to the gas connection:
- use a gas pipe with the correct dimensions, so that no
pressure loss can occur;
- the gas tap should have the CE marking;
- you should always be able to reach the gas tap.
6.4 Placing the appliance
- Make sure that combustible objects and/
or materials have a distance from the ap-
pliance of at least 500 mm;
- Always place the appliance against a wall of
non combustible and heat-resistant
material;
- Take suffi cient measures to prevent tempe-
ratures of a wall behind the chimney breast
becoming too high, including the materials
and/or objects behind the wall;
- Do not make any changes to the appliance.
!Caution - Take the adjustable height of the appliance
into account; it depends on the setting of
the adjustable feet (see fi g. 1a and fi g. 1b);
- Take the minimum construction depth of
the appliance into account; Global 70/Glo-
bal 70 XT: 362 mm (see fi g. 2a and fi g. 2b);
- If required, install the Max vent system
prior to placing the appliance; see the
manual for the Max vent system;
- Take the different construction measure-
ments into account when applying the Max
vent system; see the manual for the Max
vent system.
!Tip You can determine the construction height
of the appliance (X in fi g. 2a and fi g. 2b)
yourself.
Place the appliance as follows:
Determine the location of the appliance.
Determine the construction height of the appliance.
Provide a gas connection at the location. For details,
see section 6.3.
Make a passage for the fl ue gas discharge/combustion air
supply system with the following diameters. For details,
see section 6.5.
- Ø160 mm for a wall terminal through non combustible
material;
- Ø 250 mm for a wall terminal through combustible
material;
- Ø160 mm for a roof terminal through non combustible
material;
- Ø 250 mm for a roof terminal through combustible mate-
rial.
Place the appliance on its destined location.
The gas control is mounted under the appliance, at the bur-
ner plate. It should be disconnected and placed in the control
box at a later stage. The control box is not part of the appli-
ance's standard equipment and is available at your dealer. For
placing the gas control in the control box, see section 6.7.
Follow the procedure described below:
Disconnect the pipes from the gas control (fl exible gas
pipe, aluminium pilot-fl ame pipe and thermocouple 1).
!Caution The red wire of thermocouple 2 must
remain connected to the gas control.
Disconnect the gas control from the burner plate by
unscrewing the self-tapping screw.
Carefully unwind the red and black wires of
thermocouple 2.
Lay the gas control together with the wires of
thermocouple 2 in the direction of the control box.
- Make sure there is no dirt in gas pipes and
connections;
- Avoid kinks in the pipes.
Roll out the pipes in the direction of the control box.
Roll out the ignition cable in the direction of the control
box.
!Caution - Make sure the ignition cable cannot come
into contact with other wires;
- The data plate should remain connected to
the chain.
Place the chain with the data plate in the direction of the
control box.
Set the height of the appliance using the adjustable feet and
Make the appliance level at the same time.
- Do not place the appliance too tightly
against the back wall; this is guaranteed by
means of the spacer brackets;
- Make sure the space between the adjusta-
ble feet is kept free;
- Do not cover the appliance and/or do
not wrap it in an insulation blanket or any
other material.
6.5 Flue gas discharge / combustion air supply
system
6.5.1 General
The appliance is of the C11/C31 type.
The appliance is connected to a combined fl ue gas
Caution
Caution
Caution
Caution
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 70 in the language / languages: English, Dutch as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 70

DRU GLOBAL 70 User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info