yes
Start
2.01 Can pilot be lit?
2.03 Only one spark?
2.02 Sparking?
2.09 Ignitionprocedure
- Oval knob on gas control is on
"MAN". Set to "ON" and restart.
Retardedignitionofmain
burner(s)
Gas to main burner opens ca. 3-5
seconds after servo motor,
operating the gas valve, starts
running (sound of motor!). After
this the main burner is to ignite (at
least partially) within 10 seconds
and not with a firm noise WHOOF.
If not: no or delayed cross lighting
of main burner.
Hazardoussituation.
Stop ignition procedure straight
away and first check for:
- Position of logs or pebbles.
- Burner holes (locally) blocked.
Remove vermiculite dust.
- Vermiculite missing.
- Chips on burner.
- Vermiculite not distributed
evenly across burner(s).
PowerVent®(ifpresent)
Burner does not light. Consult
PowerVent® installation manual
how to carry out the checks below.
Check:
- 230 V to fan controller unit and
fan.
- Silicon pressure measurement
hoses:
- swapped;
- leaking or barred.
- Pressure difference set too high.
- Resistance of flue system too
high:
- adjustment (of appliance
damper and air inlet guides);
- flue length or number of bends
too large;
- dirty (e.g. cobwebs).
- Operation of the fan.
- Operation of solenoid gas valve.
- Operation of fan controller unit.
- Operation of pressure
measurement gauge.
2.11 Nopropercrosslighting
ofmainburner(s).
Go to box 2.09 and take
actions act as described for
'retarded ignition of main
burner'.
2.06 Pilot can be lit.
Does it stay alight?
2.10 Do(es) main burner(s)
ignite smoothly and across
its/their full length after first
ignition by pilot burner?
2.08 Does main burner
ignite immediately?
2.04 Check:
Receiver
- Replace missing, weak or
rechargeable batteries (not enough
power to open thermoelectric
valve).
Presenceofgasonpilotburner
Check pilot on presence of gas at
normal ignition cycle or in Manual
Mode (turn oval knob on gas control
to MAN and keep safety shut off
valve opened with a screwdriver) and
ignite pilot with a lighter.
- Pilot flame not on: Step 1.
- Pilot flame on: Step 2.
Step1:Pilothasnogas
Check:
- Gas tap open?
- Gas at gas control (line pressure at
measuring point on gas control).
- Gas flowing out of gas control? (by
loosening pilot tube at gas control).
If not: check adjustment screw pilot
flame (under black cover): sealing
not to be broken.
Sealing broken: screw should be
fully open.
- Blocking of pilot tube (kink or dirt).
- If this does not help: replace gas
control.
Step2:Pilothasgas,butno
ignition
- Electrode with 90°bended tip:
bend tip 1 mm higher.
- Spark too weak (thin and reddish).
Act as if 'no spark' in box 2.05 and
perform actions described for
ignition cable and ignition
electrode.
- Pilot flame too weak (dirty).
Remove injector (remove gland nut
and the pilot tube). See that it does
not fall away. Clean with
compressed air.
Rectify. Retry.
2.05 Check:
Ignitioncable
- Present and connected.
- Being free from metal parts or
concrete.
- Too long: cut away all excessive
length at receiver end, and
reconnect.
- Shorting out to earth: replace
ignition cable.
- Spark in wrong position:
- slide rubber sleeve on ignition
cable over ceramic of electrode.
- Replace electrode if neccessary.
Ignitionelectrode
- Straight electrode:
- oxidation (roughen electrode
with file or sand paper);
- position (4 mm from pilot burner).
- Cracks in ceramic (not always
visible): replace electrode.
Startingprocedure
After switching off/going out the
remote is locked for 120 sec. (older
versions 60 sec).
Wait 2 minutes before reigniting.
2.07
Pilotoutwhenservomotorstarts
torun?Checkthethermocouple
system.
- Measure thermocouple voltage in
mV just after servomotor starts to
run and the voltage goes down.
- Measure between red dot on
receiver and earth point on gas
control (fig. 42).
- 0 mV
- 2-3 mV
- 3-5 mV
- 6 mV and higher
- Requirement: after rectification
actions thermocouple voltage
should be 6 mV at least, just after
motor starts running!
Voltage0mV
- Thermocouple defective. Check by
replacing or measuring voltage at
end whilst heating (tip: with a
lighter).
- Short circuiting or interruptions in
circuit:
Check:
- thermocouple tight in
interruptor;
- interruptor tight in gas control;
- black wires (yellow/red end)
connected to interruptor +
receiver;
- interruptor (mount
thermocouple directly in gas
control and ignite in Manual Mode
(see 2.04).
If pilot stays on: interruptor
defective.
Voltage2-3mV
- Check pilot flame.
Too small:
- pilot dirty.
Clean up (see 2.04).
- check for pilot gas tube
tightness;
- pilot tube kinks or dirt inside;
- line pressure too low.
- Tip: thermo couple not in (correct!)
pilot flame.
Bend into flame.
Voltage3-5mV
- Appliance may work, but is too
critical.
Perform actions as described for
2-3 mV.
Voltage6mVandhigher
Voltage OK, so different cause.
- Receiver defective. Check by
dismounting black-red and yellow
control cables from receiver and
link together. Ignite fire in Manual
Mode (see 2.04). Pilot stays on:
receiver defective.
- Gas control defective if receiver is
not defective. Replace gas control.
yes
no
yes yes
no
no
no
no no
Fires with electronic ignition, fault finding: Ignition and burning
Appendix1diagnosisofmalfunctions
GB20
2.03a
- Loosen and retighten
earthing screw on gas
control.
- If this does not work:
replace receiver.
yes
yes
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Diablo Next at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Diablo Next in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Diablo Next

DRU Diablo Next User Manual - English - 20 pages

DRU Diablo Next Installation Guide - German - 36 pages

DRU Diablo Next User Manual - German - 20 pages

DRU Diablo Next Installation Guide - Dutch - 36 pages

DRU Diablo Next User Manual - Dutch - 20 pages

DRU Diablo Next User Manual - Dutch - 16 pages

DRU Diablo Next User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info