810284
26
Zoom out
Zoom in
Previous page
1/40
Next page
B
A
A
A
B
A
A
A
A
A
A
B
B
A
A
A
A
A
A
A
A
C
B
B
A
A
B
A
A
A
A
A
A
A
C
C
B
B
A
A
B
B
A
A
A
B
A
A
A
A
C
C
B
B
B
A
B
B
B
A
A
B
B
A
A
A
D
C
C
B
B
B
C
B
B
B
A
B
B
B
A
A
D
C
C
C
B
B
C
C
B
B
B
C
B
B
B
B
D
D
C
C
C
C
C
C
B
C
C
B
B
E
D
D
C
D
C
C
C
C
C
E
D
D
D
D
D
C
E
E
D
D
English
INSTALLATION MANUAL
26
Table 5: Determining permissibility concentric system with roof terminal
G20/G25.3 Total number of meters
horiz.
pipe length
Total no. of meters vertical and/or sloping pipe length
no bends
2 bends
3 bends
4 bends
5 bends
= Situation is not permissible
minimum length
Situation
A
B
C
D
E
Air inlet guide
NO
NO
NO
NO
NO
Table 6: Conditions for the adjustment of the appliance with a roof terminal
Restrictor slide
NO
YES
YES
YES
YES
Distance restrictor. in mm
OPEN
75
65
60
55
G20/G25.3
!Caution
If a roof terminal without bends is used, you must first connect a 0.8 metre concentric pipe with a 200/130 mm
diameter vertically to the appliance. After the first metre, reduce the diameter to 150/100 mm
!Caution
If a roof terminal with bends is used, you must first connect a 0.8 metre concentric pipe with a 200/130 mm
diameter vertically to the appliance. Make the system with a 200/130 mm diameter, and reduce the diameter to
150/100 mm after the last bend.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Cosmo Tunnel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Cosmo Tunnel in the language / languages: English as an attachment in your email.

The manual is 8.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Cosmo Tunnel

DRU Cosmo Tunnel User Manual - English - 28 pages

DRU Cosmo Tunnel User Manual - German - 28 pages

DRU Cosmo Tunnel Installation Guide - German - 40 pages

DRU Cosmo Tunnel User Manual - Dutch - 28 pages

DRU Cosmo Tunnel Installation Guide - Dutch - 40 pages

DRU Cosmo Tunnel Installation Guide - French - 40 pages

DRU Cosmo Tunnel User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info