Once the ‘wireless system’ has been commis-
sioned, the unit will display the actual room
temperature and the time at somewhere after
12.00 midnight (Diagram A).
Note: If this unit has replaced a standard
room thermostat and/or a programmer is
incorporated in the control system, it is
suggested that the central heating (CH) channel
is switched to ON/CONT/24HRS. Operation
of the heating times and temperatures will be
controlled by this unit.
Diagram A Diagram B
Digistat RF2 has an indicator to show when the heating system is ON or OFF,
e.g. if the SET temperature is 20°C and the actual room temperature is below
20°C a flame symbol will appear on the display (Diagram B). This indicates a
demand for heat (system will switch ON).
During normal operation, the Digistat RF2 will display actual room
temperature continuously.
SETTING THE TIME OF DAY (steps 1-4)
The diagram next to each step description shows resulting display.
1. Press “SET?” button
2. Press “Yes” (–) button. The hours will flash as shown
here. Use the + and – buttons to set correct hour.
3. Press “SET?” button again and the minutes will flash, use
+ and – buttons to set correct minute time.
4. Press “SET?” button twice to return to normal operating
mode.
PRE-PROGRAMMED TIMES AND TEMPERATURES
The Digistat RF2 comes with the following preset programme.
Symbol Setting Time Temperature
1st day time 6.30 20°C
2nd day time 8.30 16°C
3rd day time 4.30 pm 21°C
Night time 10.30 pm 7°C*
* 16°C if selector pin removed, see installation instructions
TO VIEW OR CHANGE THE FACTORY SETTINGS (
steps 5-10)
5. Press the “SET?” button until this display is shown.
6
.
P
ress the Yes (–) button again. This tells you that at 6.30,
t
he heating system will control your home at 20°C. If you
w
ish to alter the temperature use the + and – buttons.
7
.
P
ress the “SET?” button. The time will now flash. If you
w
ish to alter the switching time use the + and – buttons.
This will change the switching time in 10 minute steps.
8. Press the “SET?” button, this tells you that at 8.30, the
heating system will control your home at 16°C. If you
wish to alter this temperature use the + and – buttons.
9. Continue to press the “SET?” button as in steps 6 and 7
above to advance through the times and temperatures. If
you wish to alter any of the times and temperatures use
the + and – button, when the one you wish to alter is
flashing.
10. Continue to press “SET?” button until you
return to normal operating mode with a display similar to
the one shown here.
OPERATING MODES
The Digistat can be operated in one of three modes.
1) Timed, all preset times and temperatures
2) Continuous night temperature (useful for low limit temperature
protection when on holiday)
3) Continuous ‘DAY 1’ temperature
Use the SELECT button to change the operating mode to suit your
requirements, the symbols are positioned on the right hand side of the display.
TEMPERATURE OVERRIDE
If at anytime during normal operation, you wish to temporarily increase or
decrease the set temperature use the + or – buttons to change to your desired
setting. This can be done without entering the SET mode five seconds after
releasing the + or – button the display will revert to showing the actual room
temperature. The Digistat will now control the temperature to the override
setting until the next programmed switching time, when it will revert to the
times and temperatures you have already programmed.
BATTERY REPLACEMENT
30 days before the batteries need replacing, a battery symbol
will flash in the right hand side of the display (Diagram C).
This signifies that four 1.5V type AA
alkaline batteries will
be needed to replace the existing ones. If battery replace-
ment is carried out in this condition the programmed
settings will only be held in the memory for a maximum of
1 minute, after which re-programming may be necessary.
+
+
+
+
S
YSTEM OFF SYSTEM ON
Diagram C
Continued overleaf
090-795 Digistat RF2 Inst IssB 12/5/06 16:13 Page 3
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Drayton Erie Digistat RF2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Drayton Erie Digistat RF2 in the language / languages: English as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info