680248
13
Zoom out
Zoom in
Previous page
1/209
Next page
VigorSwitch P2280 User’s Guide
5
Blinking The system is sending or receiving data through
the port.
Port 1 ~ 24
Off The port is disconnected or the link is failed.
On (Green) The device is connected with 1000Mbps.
On (Amber) The device is connected with 10/100Mbps.
Blinking The system is sending or receiving data through
the port.
Combo for
Port 25 ~ 28
(RJ 45
LNK/ACT)
Off The port is disconnected or the link is failed.
On (Green) The device is connected with 1000Mbps.
On (Amber) The device is connected with 10/100Mpps.
Blinking The system is sending or receiving data through
the port.
SFP LNK/ACT
Off The port is disconnected or the link is failed.
C
C
o
o
n
n
n
n
e
e
c
c
t
t
o
o
r
r
E
E
x
x
p
p
l
l
a
a
n
n
a
a
t
t
i
i
o
o
n
n
Interface Description
RJ 45 LNK/ACT Port 1 ~ 24
PoE for Port 1 ~ 24
Port 1 to Port 24 can be used for Ethernet
connection and PoE connection, depending on the
device connected
.
SFP LNK/ACT Port 25 ~ 28
Port 25 to Port 28 are used for fiber connection.
Console
Used to perform telnet command control.
Power inlet for AC input (100~240V/AC, 50/60Hz).
Note:
Power Output –
IEEE 802.3af Max. 15.4W Output Supported
IEEE 802.3at Max. 30W Output Supported
PoE Power Budget--
340 Watts (Max)
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch P2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch P2280 in the language / languages: English as an attachment in your email.

The manual is 3,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info