680245
86
Zoom out
Zoom in
Previous page
1/120
Next page
VigorSwitch P1280 User’s Guide
80
V
V
I
I
-
-
1
1
L
L
L
L
D
D
P
P
LLDP is a one-way protocol; there are no request/response sequences. Information is
advertised by stations implementing the transmit function, and is received and processed by
stations implementing the receive function. The LLDP category contains LLDP and LLDP-MED
pages.
V
V
I
I
-
-
1
1
-
-
1
1
P
P
r
r
o
o
p
p
e
e
r
r
t
t
i
i
e
e
s
s
This page allows a user to set general settings for LLDP.
Available settings are explained as follows:
Item Description
LLDP State Enable – Enable LLDP protocol on this switch.
Disable – Disable LLDP protocol on this switch.
Transmission Interval Select the interval at which frames are transmitted. The
default is 30 seconds, and the valid range is 5–32768seconds.
Holdtime Multiplier Select the multiplier on the transmit interval to assign to TTL
(range 2–10, default = 4).
Reinitialization Delay Select the delay before a re-initialization (range 1–10 seconds,
default = 2).
Transmit Delay Select the delay after an LLDP frame is sent (range 1–8192
seconds, default = 3).
Apply Save the settings or changes to the switch.
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch P1280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch P1280 in the language / languages: English as an attachment in your email.

The manual is 2,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info