This page is used to configure port settings for Storm Control. The configuration result for
each port will be displayed on the table listed on the lower side of this web page.
Available settings are explained as follows:
Item Description
Ports Use the drop down list to select the port profile (GE1 to GE28)
or profiles.
Storm Control Disable – Disable the storm control configuration for the
selected port profile.
Enable – Enable the storm control configuration for the
selected port profile.
Limiting Rate Check the box(es) to enable strom control rate limited for
Broadcast, Unknown Multicast and/or Unknow Unicast packet.
Broadcast – Specify the storm control rate for Broadcast
packet. Value of storm control rate, Unit: Kbps (Kbits
per-second). The range is from 16 to 1000000.
Unknown Multicast – Specify the storm control rate for
unknown multicast packet. Value of storm control rate, Unit:
Kbps (Kbits per-second). The range is from 16 to 1000000.
Unknown Unicast - Specify the storm control rate for
unknown multicast packet. Value of storm control rate, Unit:
Kbps (Kbits per-second). The range is from 16 to 1000000.
Action Select the state of setting.
Drop – Packets exceed storm control rate will be dropped.
Shutdown - Port exceeds storm control rate will be shutdown.
Apply Save the settings or changes to the switch.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch P1280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch P1280 in the language / languages: English as an attachment in your email.

The manual is 2,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info