680242
207
Zoom out
Zoom in
Previous page
1/211
Next page
VigorSwitch G2280 User’s Guide
19
9
Parameter
value/LAN
10Base 100Base 1000Base
Max. collision
domain DTE to
DTE
100 meters 100 meters for
UTP
412 meters for
fiber
100 meters for
UTP
316 meters for
fiber
Max. collision
domain with
repeater
2500 meters 205 meters 200 meters
Slot time
512 bit times 512 bit times 512 bit times
Interframe Gap
9.6us 0.96us 0.096us
AttemptLimit
16 16 16
BackoffLimit
10 10 10
JamSize
32 bits 32 bits 32 bits
MaxFrameSize
1518 1518 1518
MinFrameSize
64 64 64
BurstLimit
Not applicable Not applicable 65536 bits
In full-duplex operation mode, both transmitting and receiving frames are processed
simultaneously. This doubles the total bandwidth. Full duplex is much easier than half duplex
because it does not involve media contention, collision, retransmission schedule, padding bits
for short frame. The rest functions follow the specification of IEEE802.3. For example, it must
meet the requirement of minimum inter-frame gap between successive frames and frame
format the same as that in the half-duplex operation.
Because no collision will happen in full-duplex operation, for sure, there is no mechanism to
tell all the involved devices. What will it be if receiving device is busy and a frame is coming
at the same time? Can it use “backpressure” to tell the source device? A function flow control
is introduced in the full-duplex operation.
207


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch G2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch G2280 in the language / languages: English as an attachment in your email.

The manual is 3,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info