680239
77
Zoom out
Zoom in
Previous page
1/83
Next page
VigorSwitch G1240 User’s Guide
71
Parameter description:
Port/Group: Display the Port/Group number.
Path Cost: The range is 0 – 200,000,000. In the switch, if path cost is
set to be zero, the STP will get the recommended value
resulted from auto-negotiation of the link accordingly and
display this value in the field of Path Cost Status.
Otherwise, it may show the value that the administrator
sets up in Configured Path Cost and Path Cost Status.
802.1w RSTP recommended value:
(Valid range: 1 – 200,000,000)
10 Mbps: 2,000,000
100 Mbps: 200,000
1 Gbps: 20,000
Default: auto
Edge Port: Display if edge function is enabled or not for such port.
P2p Port: Display if point-to-point function is enabled or not for
such port.
A port is a point-to-point link. From RSTP’s view, it is in
full-duplex mode, but in half-duplex mode for shared
link.
Protocol: Display if such RSTP protocol is enabled or not.
Port State: Display the status (including Non-STP / STP / RSTP) for
each port.
3
3
.
.
1
1
1
1
.
.
3
3
I
I
G
G
M
M
P
P
S
S
t
t
a
a
t
t
u
u
s
s
Function name:
IGMP Status
Function description:
Display IGMP status. In Fig. 4-29, the window shows VLAN ID for each multicast group.
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch G1240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch G1240 in the language / languages: English as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info