28
collision. The arbitrator will arbitrate who should gain the media. The arbitrator is a
distributed mechanism in which all stations contend to gain the media. Please refer to
“What’s the Ethernet” for more details.
In the figure listed below, assumed in half duplex, you will see some ports of the switch are
linked to a shared HUB, which connects many hosts, and some ports just are individually
linked to a single host. The hosts attached to a shared hub will be in the same collision
domain, separated by the switch, and use CSMA/CD rule. For the host directly attached to
the switch, because no other host(s) joins the traffic contention, hence it will not be
affected by CSMA/CD. These LAN segments are separated in different access domains by
the switch.
M
M
i
i
c
c
r
r
o
o
-
-
s
s
e
e
g
g
m
m
e
e
n
n
t
t
a
a
t
t
i
i
o
o
n
n
:
:
To have a port of the switch connected to a single host is referred to as micro-segmentation.
It has the following interesting characteristics.
z There is no need the access contention (e.g.Collision). They have their own access
domain. But, collision still could happen between the host and the switch port.
z When performing the full duplex, the collision vanishes.
z The host owns a dedicated bandwidth of the port.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch G1240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch G1240 in the language / languages: English as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info