499407
8
Zoom out
Zoom in
Previous page
1/13
Next page
8
Now screw the castor (26) onto the retaining bolt (25) (Fig.
16).
Lift the door element with the pre-assembled bearing
bolt (27) onto the installation plate (12), and slide the
bearing into place.
To assemble the upper bearing (Fig. 18), you will need the
installation plate (28), which is first loosely assembled
using the two threaded bolts (29), the nuts (30) and lock-
washers (31).
Swing the door element over the installation plate (28) so
that the upper bearing point of the door element (32) is
positioned opposite the opening in the installation plate
(28).
Now let the installation plate (28) drop down over the
upper bearing, and tighten the two nuts (30) firmly (Fig.
18).
29
28
30
31
Fig. 18
32
ÆElectrical connection of the elements
All 3 elements have their electrical connections at the
top, and are connected to the control unit (33) by means
of the 3 plugs (34 - 36) (Fig. 19).
Fig. 19
3334
35
36
ÇInstalling the upper trim panels
Finally, fit the three trim panels (37) around the upper
edge of the system (Fig. 20), using for each panel two
self-tapping screws (38) on the outside, and two M4
screws in the central area.
Ensure that a distance sleeve is placed between the
trim panel and rear wall of the unit at each attachment
point.
32
28
37
38
Fig. 20
ÈInstallation of main connection cable / cover
panel
The main connection cable (39) is pre-assembled to
the control unit (33), and lies rolled up on the exhaust
unit.
Take the cable (39) and lead it down along the side of
the system (Fig. 21).
Then fit the cable tension-relief device (40) (from the
accessory pack) to the cable (Fig. 22).
Now remove the cover panel (41) from package 3, and
fit it as shown in Fig. 23.
Note: The existing screws in the rear walls are used
for the attachment of the cover panel (41). These screws
must be removed before fitting the cover panel.
Fig. 21
33 = Control unit
34 = Connection cable, right element
35 = Connection cable, left element
36 = Connection cable, door element
39 = Main connection cable
39
39
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dr. Kern Tancan 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dr. Kern Tancan 4000 in the language / languages: English as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info