695929
34
Zoom out
Zoom in
Previous page
1/153
Next page
Controlling combustion air
The appliance has various features for air control; see
next figure.
1
2
3
09-20021-081
The primary air inlet regulates the air under the grate
(1).
The secondary air inlet regulates the air for the glass
(air wash) (2).
The back wall has permanent vents (3) below the
baffle plate that allow for post-combustion.
Advice
Never burn wood with an open door.
Regularly burn wood with intense roaring fires.
If you burn at a low setting frequently, tar and
creosote may be deposited in the flue. Tar and
creosote are highly combustible substances.
Thicker layers of these substances may catch
fire if the temperature in the flue increases sud-
denly. By allowing the fire to burn very
intensely regularly, layers of tar and creosote
will disappear.
Low intensity fires can also cause tar deposits
on the stove window and door.
When the outside temperature is mild, it is bet-
ter to burn wood intensely for a few hours
instead of having a low intensity fire for a long
period of time.
Control the air supply using the air vent.
The air inlet not only supplies air to the fire but
to the glass as well, so that it does not quickly
become dirty.
Open the primary air inlet for the time being if the air
supply by the secondary air inlet is inadequate or if
you want to fan the fire.
Topping up with a few logs regularly is better than
adding many logs in one go.
Extinguishing the fire
Do not add fuel and just let the fire go out. If a fire is
damped down by reducing the air supply, harmful sub-
stances will be released. For this reason, the fire
should be allowed to go out naturally. Keep an eye on
the fire until it has gone out. All air inlets can be closed
once the fire has died completely.
Removing ash
After wood has been burnt, a relatively small amount
of ash remains. This ash bed is a good insulating layer
for the stove base plate and improves combustion. It
is a good idea to leave a thin layer of ash on the stove
base plate.
The flow of air through the fire plate must not be
obstructed, however, and no ash may be allowed to
accumulate behind a cast-iron inner plate. Remove
the excess ash regularly.
Using the glove supplied, remove the ash pan and
empty it. Replace the ash pan and close the door.
Fog and mist
Fog and mist hinder the flow of flue gases through the
flue. Smoke can blow back and cause a stench. If it is
not strictly necessary, it is better not to use the stove
in foggy and misty weather.
Resolving problems
Refer to the appendix "Diagnostic diagram" to resolve
any problems in using the appliance.
Maintenance
Follow the maintenance instructions in this chapter to
keep the appliance in good condition.
12
Subject to change because of technical improvements
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dovre Brut at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dovre Brut in the language / languages: English, German, Dutch, French, Italian, Spanish, Norwegian as an attachment in your email.

The manual is 8,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info