Appendix 4: Diagnosis diagram
Problem
Wood will not stay lit
Gives off insufficient heat
Smoke emissions into the room when adding wood
Fire in appliance is too intense, is hard to adjust
Deposit on the glass
possible cause possible solution
Insufficient draught A cold flue usuallyfails to create sufficient draught. Follow the instruc-
tionsfor starting a fire in the ‘Use’ section; open a window.
Wood too damp Use wood with no more than 20% moisture.
Logs too large Use smallpieces of kindling. Use split logs no larger than 30 cm in cir-
cumference.
Wood stacked incorrectly Stackthe logs in a way that allows adequate air flow between the
logs (open stacking, see "Burning wood")
Flue does not work properly
Check whether the chimney meets the requirements: at least 4
metres high, correct diameter, well insulated, smooth inside, not too
many bends, no obstructions in chimney (bird's nest, too much soot
deposit), hermetically tight (no chinks).
Chimney stack incorrect Sufficiently high above the roof, no obstacles in the vicinity
Air inlets set incorrectly Open the air inlets completely.
Appliance connected to the chimney
incorrectly Connection should be hermetically tight.
Vacuum in area in which the appliance is
installed Switch off extraction systems.
Insufficient supply of fresh air Provide an adequate air supply; if necessary, use outside air con-
nection.
Bad weather
? Inversion (reversed air flow in chimney
because of a high outside temperature),
extreme wind speeds
We recommend you don't use the appliance in the case of inversion.
If required, install an extra hood on the flue to increase the draught.
Draught in the living room Avoid draught in the living room, do not place the appliance near a
door or heating air ducts.
Flames touch the glass Make sure the wood isnot positioned too close to the glass. Slide the
primary air inlet cover closer to the "Closed" position.
Appliance is leaking air Checkthe door sealsand appliance joints.
DOVRE
30 Subject to change because of technical improvements
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dovre 540W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dovre 540W in the language / languages: English, German, Dutch, French, Spanish, Norwegian as an attachment in your email.

The manual is 5.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info