571276
26
Zoom out
Zoom in
Previous page
1/38
Next page
wijzigingen op grond van technische verbeteringen voorbehouden
26
2.5 Outlet protection
The appliance is tted with thermal outlet protection which cuts out the pilot light and thus
turns off the main burner in the event of leakage of combustion gases from the draught
diverter.
The protective device is a thermal switch which opens an electrical contact if a set
temperature is exceeded and thus interrupts power to the thermocouple. This causes the
control block to turn off the gas supply to the main burner and pilot light. The appliance
can only be relit when the protective device has cooled down. The thermostat cannot just
be switched off. Call your installer if the outlet protection is activated frequently.
Possible causes for the activation of the outlet protection include:
A bad connection between the appliance and the outlet ue.
The outlet ue is wholly or partly blocked by falling debris or similar.
Flue draught is too weak.
An open kitchen with an excessively powerful cooker hood.
On replacement, only use the original thermal switch, not alternatives.
3 Maintenance
At the beginning of each burning season we recommend thorough dust removal from the
appliance.
Damage to the paint can easily be repaired using a spray can of "Thermoblack". Initially
the paint on your stove will still give off an odour. This should disappear after a while.
Never operate the appliance with a cracked or broken window.
Every year, have the appliance checked and serviced by your installer.
What to do if there is a smell of gas:
Open all the windows of the space fully.
Close off the space where you smell the gas from the rest of the building.
Close the tap on your gas meter.
Extinguish and avoid all open res and ames.
Notify your natural gas supplier or your installer.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dovre 425GA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dovre 425GA in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dovre 425GA

Dovre 425GA Additional guide - English, German, Dutch - 1 pages

Dovre 425GA User Manual - Dutch - 24 pages

Dovre 425GA Additional guide - French - 1 pages

Dovre 425GA User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info