3.2.2. Assembly of the smoke dome and of the flue collar
The smoke dome must
be fixed to the top of
the device and attached
by means of the clamps
supplied. Assure proper
sealing by means of the
kit or paste supplied.
It is recommended to
install the smoke dome
with its exhaust back-
wards. In case of proper
draft, it may be turned
up to 90° to the left or to
the right if required for
installation. In case of
lower draft, an angle of
maximum 60° is recom-
mended.
The flue collar can be
installed either horizon-
tally or vertically. Fix the
flue collar on the smoke
dome with 2 bolts
M6x30, 2 nuts M6, and
4 collars Ø6xØ12. Assure proper sealing with kit or paste.
3.2.3. Installation of the ashtray (if applicable)
The optional ashtray is installed as follows:
Lift the plate in the middle of
the bottom brick; insert a
screwdriver into the hole to
lift the brick (if necessary, tap
the brick with a hammer to
loosen it).
Extrude the pre-cut plate
from the bottom heat shield.
Clean the sealing edge and
put the supplied rope (diam.
6 mm) in the groove; install
then the ashtray holder.
Tighten the 4 plate screws in
the ashtray holder and assure
proper sealing with kit or
paste.
You can now install the ashtray and the grid.
KIT
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dovre 2000CBGL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dovre 2000CBGL in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info