784270
14
Zoom out
Zoom in
Previous page
1/76
Next page
14
R1, R1 Bi-stable latching relay #1, max. 24 V DC/AC, 1 A. Security feature: The relay
keeps its state even in the case of loss of power. You can configure the default
state of the relay (open/close) via the DoorBird App. These ports can be used
to connect e.g. an electric door opener. The device does not supply power to
the connected device. The power supply for the electric door opener must be
installed separately.
When wiring an electric door opener directly to a door station, there is a
risk that the electric door opener could be tampered by unauthorized
third parties (e. g. by breaking the door station and short-circuiting the
wiring of the door opener). Therefore, we generally recommend the use of
a remote safety relay mounted indoors (e. g. DoorBird I/O Door Controller
A1081) for wiring an electric door opener for a more secure installation in
your home.
E1, E1 Digital input (0 V, 0 A (NO)), for door opener button, max. 0 V DC/AC, 0 A.
These ports can be used to connect e.g. a door opener button inside the home. It
will can trigger the bi-stable latching relay of the device (R1, R1)
NOTICE Please make sure to add no voltage on these ports. Extra voltage may
destroy the device immediately.
15 VDC - 15 V DC Power supply input, negative pole (-). Please connect the black wire of
the power supply unit (mains adapter) supplied with this device if you do not
power the device using PoE. We only recommend PoE.
NOTICE Do not power the device simultaneously via the power supply from the
power supply unit (mains adapter) and the power supply via PoE.
15 VDC + 15 V DC Power supply input, positive pole (+). Please connect the red wire of the
power supply unit (mains adapter) supplied with the device here, if you do not
power the device using PoE. We only recommend PoE.
NOTICE Do not power the device simultaneously via the power supply from the
power supply unit (mains adapter) and the power supply via PoE.
COM1 Jack for authorized peripherals of Bird Home Automation which will be released
in the future, e.g. keypad
CB2 Jack for second call button.
CB1 Jack for first call button.
NOTICE The jacks “CB1”, “CB2” and “COM1” on the rear side of the Main Electrical Unit must only be used to
connect components certified by Bird Home Automation.
CALL BUTTON PORT
SWITCH
(4 PIN) Use the four wire call-button cable provided to connect the call-button to the Main
Electrical Unit (already connected in delivery condition to the jack ”CB1“/ ”CB2“).
NOTICE Please take care when connecting the cables and wires. Connecting the cables and wires the wrong way
may damage the device. Wires without insolation material must not protrude out of the green screw
connection terminal, it may lead to electrical short and damage the device.
R1
R1
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Doorbird D1102V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Doorbird D1102V in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 13.29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Doorbird D1102V

Doorbird D1102V Additional guide - All languages - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info