cannot infiltrate.
Use LOCTITE 577 to make all connections, so as to prevent
fuel leakages.
To connect the fuel tank to the generator, use a 6x13mm
rubbercoated tube, of the same type used for the genset
and suitable for unleaded petrol. For the extension, use the
ties and filter provided. It is advisable to use fuel hose
AG118 (accessory) for the connection from tank to refuelling
mouth.
IMPORTANT
Model 5500 does not need fuel tank, since it is standard
fitted inside the genset casing.
CONNECTION TO GAS CANISTER
CAUTION
For the LPG genset, withdraw the gas from the upright
canister and the vehicle's service regulator and from the
upper part, so that gas enters the genset at low pressure
and in the gaseous state.
(Minimum recommended pressure: 0.30 mbar)
3.0 GENERAL OPERATION
IMPORTANT
The firm disclaims any responsability for damages arising
from malfunctioning of the generator.
3.1 DESCRIPTION OF GENERATOR AND
FUNCTIONING
The generator consists of an endothermic petrol engine
connected to an alternator which produces both alternate
and direct current.
The unit comes in a soundproof casing made of pressed
steel plate and insulated with special deadening materials.
Fuel comes to the combustion engine through a pump
which is standard fitted on the unit itself.
3.2 SAFETY ADVICE
The unit is housed within a perfectly closed casing. Therefore,
there is no danger of accidental contacts with hot or moving
parts or wires under voltage.
The door of the unit is fitted with lock and key and should
not be left within the reach of children or nonauthorised
persons.
DANGER
The unit shall be used only and exclusively with the door
closed.
Keep inflammable substances like petrol, paints, solvents,
etc. away from the generator.
Do not let hot parts of the genset come into contact with
inflammable materials.
Do not fill up with the engine running if the tank is placed
close to the generator.
Do not touch the generator or its connections with wet
hands.
Do not replace the fuses or thermal switches with new
ones of higher amperage.
Any check of the electrical parts shall be made with
engine stopped and by authorised technicians only.
The generator is manufactured according to the safety rules
given in the Conformity Declaration.
3.3 NOISE LEVELS
The generator has been submitted to a noise emission test
at a qualified ISTEDIL lab, where all the necessary tests were
carried out and EC Certificate No.I225/92 issued, stating
following results:
Measured according to: EC DIRECTIVE 84/536
NOISE LEVEL:
Mod. 2500 .......................................... LwA 85
Mod. 4000 .......................................... LwA 87
Mod. 5500 .......................................... LwA 87
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic T2500H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic T2500H in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info