RMV5301, RMV5305 Connecting the refrigerator
23
AC power
Connect the refrigerator with the mains plug to an AC socket.
DC power
Please note the following cable sizes:
< 6m (interior): 4mm
2
> 6m (interior): 6mm
2
Connections D+ and S+: 1 mm2
Cable fed via drawbar (caravans only): 2.5 mm2
Secure the power supply line to the heating element (connections F and G) with
a 15 A fuse and the line to lighting/electronics (connections B and C) with a 2 A
fuse.
Connect the heating element (connections F and G) with the shortest possible
cable.
Run the power supply line to the heating element (connections F and G) via a
relay controlled by an ignition lock to prevent the vehicle battery from completely
discharging if the engine is switched off accidentally (fig. f, page 11).
Connect a DC permanent supply to the connection for lighting/electronics
(connections B and C).
11 Gas valve
12 DC power outlet
13 Gas valve supply line
A Optional connections to DC power outlet
B Negative terminal (–) DC permanent supply for electronics
C Positive terminal (+) DC permanent supply for electronics
D Connection D+ (only for RMV5305)
E Connection S+ (only for RMV5305)
F Positive cable of the heating cartridge
G Earth cable of the heating cartridge
Item Description
RMV530x-I-West.book Seite 23 Mittwoch, 30. Oktober 2019 10:50 22
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RMV5305 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RMV5305 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RMV5305

Dometic RMV5305 User Manual - English, German, Dutch, French, Italian - 136 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info