Installing the refrigerator RML9xxx
18
The refrigerator must be installed so that it is easily accessible for service work,
easy to de-install and install and can be easily removed from the vehicle.
The distance between the refrigerator and the rear wall must be min. 15 mm –
max. 25 mm (fig. 5, page 5).
The refrigerator must be installed in a recess so that it stands firm when the vehicle
is in motion. Note the following dimensions here (H x W x D in mm):
RML9330/9331/9335: 1293 x 420 x 586.5 (fig. 1, page 3)
RML9430/9431/9435: 1293 x 468 x 553 (fig. 2, page 3)
The outer wall must be fitted with an air inlet vent (fig. 31, page 4) and an outlet
vent (fig. 32, page 4) with ventilation grilles so that the heat generated can be
easily released to the outside:
Air inlet vent: Fit the ventilation grille as flush as possible to the floor of the
installation niche with a minimum cross-section of 500 cm2.
Outlet vent: fit as far above the refrigerator as possible.
The distance between the air inlet and outlet vents must be at least 1050 mm
(fig. 4, page 4).
Fit a heat conduction plate (fig. 33, page 4) above the refrigerator so that the
heat does not accumulate in the vehicle.
If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig. 34, page 4) must be provided in the floor for
releasing leaked gas.
A distance of more than 25 mm between the refrigerator and rear wall leads to
poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator to create adequate air inlet and outlet
ventilation (fig. 5, page 5). Use a ventilation plate, for example, to do this.
If the minimum distance between the air inlet and outlet vents cannot be met, a
roof vent must be installed instead of the air outlet vent.
The roof vent should be installed directly above the back of the refrigerator as
far as this is possible. Use an air duct (fig. 61, page 5) if you need to install
the roof vent offset, otherwise heat will accumulate there.
The distance between the air inlet vent and the roof vent must be at least
1350 mm (fig. 6, page 5).
If a roof air conditioner is provided, the distance between the roof vent
(fig. 71, page 6) and the air outlet of the roof air conditioner (fig. 72,
page 6) must be at least 300 mm.
The refrigerator must not be installed at the side of the air inlet and outlet vents as
this leads to poor performance and increases the power consumption of the
refrigerator.
The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
RML9xxx-I-West.book Seite 18 Donnerstag, 7. Dezember 2017 11:24 11
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RML 9335 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RML 9335 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RML 9335

Dometic RML 9335 Installation Guide - Dutch - 59 pages

Dometic RML 9335 User Manual - Dutch - 61 pages

Dometic RML 9335 Installation Guide - French - 59 pages

Dometic RML 9335 User Manual - French - 61 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info