625962
23
Zoom out
Zoom in
Previous page
1/28
Next page
23
Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use
liquid gas (propane) - under no circumstances should town gas or
natural gas be used.
An AGA Approved LP Regulator must be fitted to the gas supply.
The pressure regulator must concur with the operating pressure specified
on the data plate of the appliance. The operating pressure corresponds to
the standard pressure of the country of specification.
Only one connection pressure is permissible for any one vehicle. A plate
showing the permanent, clearly legible notice must be displayed in full view
at the point where the gas cylinder is installed.
This appliance is not suitable for connection with a Flexible Hose.
Inflamable material should not be in immediate proximity to the burner.
The gas connection to the appliance is 1/8"BSP Female.
The gas connection may only be carried out by authorized personnel
6.7
Before Leaving - Check all connections for gas leaks with soap and water. DO
NOT use a naked flame for detecting leaks. Ignite the burner to ensure correct
operation of gas valve, burner and ignition. When satisfied with the appliance,
please instruct the user on the correct method of operation. In case the appli-
ance fails to operate correctly after all checks have been carried out, refer to the
authorised service provider in your area.
Gas pressure
Refer to data label for test point pressure.
The refrigerator must be equipped with a gas cock in the supply line to allow the supply to
be disconnected. Such a cut-out device must be readily accessible to the user.
AATTTTEENNTTIIOONN
20 Nm
max
15 Nm
max
Test point
Connection of gas supply
Gas burner
SW 14
SW 17
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RM7801L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RM7801L in the language / languages: English as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RM7801L

Dometic RM7801L User Manual - German - 30 pages

Dometic RM7801L User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info