RM10.5(S)(T), RMS10.5(X)(S)(T) Connecting the refrigerator
27
DC power
!
A
Please note the following cable sizes (fig. l, page 13):
Connections heating element:
<6 m (in the interior): 6mm
2
>6 m (in the interior): 10 mm2
Cable fed via drawbar (caravans only): 2.5 mm2
Connections electronics: 0.75 mm2
Connections D+ and S+: 0.75 mm2
Assemble your DC socket as follows (fig. k, page 11):
Connect A and C to the positive pole of the battery.
Connect D and F to Connect D and F to ground.
Connect B to the D+ signal.
The electronics of the refrigerator uses the signal D+ of the alternator to
detect the running engine. In automatic mode, the refrigerator selects the
most favorable mode available. The refrigerator is only operated with direct
current when the vehicle engine is running.
Connect E to the CI-BUS.
Connect 10 with the S+ signal (optional).
Protect the supply line A with a 2 A fuse in the power distribution box of the
vehicle.
Protect the supply line C with a 15 A fuse in the power distribution box of the
vehicle.
Run the supply line C via an ignition-controlled relay.
This prevents the battery from completely discharging if the engine is switched
off accidentally.
WARNING! Fire hazard
The supply line to the heating element must be protected with a 15 A
fuse.
The supply line to the electronics must be protected with a 2 A fuse.
NOTICE!
The respective positive and negative supply lines of the DC connections
for electronics (fig. k16, page 11) and heating element (fig. k17,
page 11) may not be joined with one another and carried on a single
wire. This can cause electrical interference or damage to electrical com-
ponents.
RM10_RMS10-I-EMEA18.book Seite 27 Mittwoch, 29. April 2020 7:31 07
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RM10.5S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RM10.5S in the language / languages: All languages as an attachment in your email.

The manual is 9,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RM10.5S

Dometic RM10.5S User Manual - All languages - 452 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info