14
Fig. 21
Fig. 25
Seal the mounting frame
making it waterproof
(
does not apply for
mounting frames with
integral seal
).
1
Fig. 22
Insert frame and screw
into position
2
To install the ventilation grilles, cut two rectan-
gles (451 mm x 156 mm) in the outer wall of the
vehicle (
for position of the cuts, see point 4.2
).
Fig. 23
Insert and lock ventilati-
on grille.
3
Fig. 24
Clip the insert for flue
gas duct in position (
only
for L100 upper ventilati-
on system kit
).
4
Insert winter cover.
5
The exhaust gas duct system must be made in
such a manner as to achieve a complete extrac-
tion of combustion products to the outside of
living space. The duct system must slope in an
upward direction in order to avoid a build-up of
condensate. The type of exhaust gas duct
shown in Fig. 26 allows the side installation of
the winter cover.
4.4 Exhaust gas duct and instal-
ling the fume flue
An installation other than described will
reduce the cooling capacity and jeopardise
the manufacturer's warranty/product liabi-
lity.
CAUTION!
Installing the standard fume flue (Fig. 26)
1. Connect T-piece (E) to adaptor (F) or flue
pipe (K) as required and affix with screw (G).
Ensure that heat baffle (H) is lodged in the cor-
rect position.
2. Insert flue pipe with cover plate (C) through
the appropriate aperture in the upper frame (I)
and connect to T-piece (E). If necessary, shorten
flue pipe (C) to the required length.
3. Insert LS 100 ventilation grille (D) into moun-
ting frame (I) and fasten, using the locking
handle on the left of the grille.
4. Put cap (B) on flue pipe (C).
5. Insert extractor insert (A) into ventilation gril-
le (D).
Installation