23
Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use
liquid gas (propane) - under no circumstances should town gas or
natural gas be used.
An AGA Approved LP Regulator must be fitted to the gas supply.
The pressure regulator must concur with the operating pressure specified
on the data plate of the appliance. The operating pressure corresponds to
the standard pressure of the country of specification.
Only one connection pressure is permissible for any one vehicle. A plate
showing the permanent, clearly legible notice must be displayed in full view
at the point where the gas cylinder is installed.
This appliance is not suitable for connection with a Flexible Hose.
Inflamable material should not be in immediate proximity to the burner.
The gas connection to the appliance is 1/8"BSP Female.
The gas connection may only be carried out by authorized personnel
6.7
Before Leaving - Check all connections for gas leaks with soap and water. DO
NOT use a naked flame for detecting leaks. Ignite the burner to ensure correct
operation of gas valve, burner and ignition. When satisfied with the appliance,
please instruct the user on the correct method of operation. In case the appli-
ance fails to operate correctly after all checks have been carried out, refer to the
authorised service provider in your area.
Gas pressure
Refer to data label for test point pressure.
The refrigerator must be equipped with a gas cock in the supply line to allow the supply to
be disconnected. Such a cut-out device must be readily accessible to the user.
AATTTTEENNTTIIOONN
20 Nm
max
15 Nm
max
Test point
Connection of gas supply
Gas burner
SW 14
SW 17