Electrical installation
Electrical installation may only be carried out by authorized personnel.
The connection cables must be laid in such a way that they do not come
in contact with hot components of the unit/burner or with sharp edges.
The electrical installation must comply with national regulations.
It is advisable to run the incoming supply through an on-board fuse or
automatic circuit breaker. The power cable must be laid in such a way
that it does not come in contact with hot components of the unit/burner
or with sharp edges.
Changes at the internal electrical installation or the connection of other
electrical components (e.g. external fan) to the internal wiring of the
appliance will expire any claims from guarantee and product liability!
Power line connection
The power must be supplied via a properly earthed socket outlet or hard-
wired connection.
Where a socket outlet is used for the mains connection lead, the outlet
must be freely accessible.
It is advisable to run the incoming supply through an on-board fuse or automatic
circuit breaker.
The power cable must be laid in such a way that it does not come in contact with hot
components of the unit/burner or with sharp edges.
If the connection cable is damaged it must be replaced by the Customer
Service at Dometic, or by respectively authorized personnel, in order to
prevent any hazards.
Battery connection
The machine's mains 12V connection cable is connected (observing correct
polarity) to a terminal strip. The cabling must be direct and by the shortest possible
route to the battery and alternator respectively.
The 12V circuit must be protected with a 20A fuse.
The heating element circuit must be connected to the vehicle battery by a suitable
ignition operated relay in order that the 12V supply is only live while the vehicle
ignition is switched on. The connection C/D (interior light, electronics ; cable black /
violet) must be permanently attached, and must not be cut-out when the vehicle
ignition key is turned off. This can be realised with an on-board habitation battery i.e.
This 12V permanently connection must be protected with a 2A fuse!
If the appliance is installed in a caravan the respective leads for 12V+
and 12V- the connections A/B and C/D must not be connected to each
other on the caravan-side)
6.8
6.8.1
6.8.2
6 mm
²
< 6 m
10 mm
²
> 6 m
min 2,5 mm
²
Cross-sectional area of cable Length of cable
Motorcaravan
Caravan (inside)
Caravan (outside)
2,5mm²
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RM 7651 L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RM 7651 L in the language / languages: English as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RM 7651 L

Dometic RM 7651 L User Manual - German - 30 pages

Dometic RM 7651 L User Manual - Dutch - 29 pages

Dometic RM 7651 L User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info