The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
The gas connection may only be carried out by a qualified
personnel.
26
BE X
DK X
DE XX
FI X
FR X
GR XX
IE X X
IS X
IT X
LU X X
NL X X
NO X
AT XX
PT X X
SE X
CH X X
ES X
UK X X X
Category I
3P(30)
I
3P(37)
I3P(50) I3+ I
3B/P(50)
I
3B/P(30)
mbar 30 37 50 28-37 30-37 50 30
Gas-pressure
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
The refrigerator must be equipped with a gas cock
(C) in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the user.
C
SW 14
SW 17
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic RM 7361L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic RM 7361L in the language / languages: English as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic RM 7361L

Dometic RM 7361L User Manual - German - 31 pages

Dometic RM 7361L Installation Guide - Dutch - 31 pages

Dometic RM 7361L User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info