Installation FreshJet3000
16
8.3 Installing in an existing opening
I
See fig. 8, page 5
Remove all screws and fixtures of the existing roof hatch or air conditioner.
Take out the roof hatch or air conditioner.
See fig. 9, page 5
Remove the sealant around the opening using a scraper or similar tool.
See fig. 0, page 5
A
Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710, Selleys Butyl Mastic, Bostik ezycaulk
butyl sealant, or similar products).
8.4 Laying the connecting cables
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see Technical data in Operating Manual).
Select the cross-section of the cable corresponding to the length:
Length < 7.5 m: 1.5 mm²
Length > 7.5 m: 2.5 mm²
See fig. a, page 5
Make an opening on one side in order to feed through the electrical power
supply cable.
Feed the 240 Vw cable through the opening into the vehicle interior.
NOTE
Existing roof hatch openings in accordance with fig. 8, page 5 are suita-
ble for installing the roof air conditioner.
Dispose of all waste material, glue, silicone and seals separately. Observe
the disposal guidelines.
The manufacturer only assumes liability for parts included in the scope of
delivery. The validity of the warranty expires if the device is installed
together with third-party parts.
NOTICE!
Observe the sealant manufacturer’s instructions.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components before car-
rying out work on them!
FreshJet3000--INM.book Seite 16 Donnerstag, 12. März 2020 11:39 11
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic FreshJet 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic FreshJet 3000 in the language / languages: All languages as an attachment in your email.

The manual is 6,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic FreshJet 3000

Dometic FreshJet 3000 User Manual - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish - 360 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info