549226
16
Zoom out
Zoom in
Previous page
1/384
Next page
EN
Installation Dometic FreshJet
12
8.3 Installing in a roof hatch opening already provided
I
See fig. 6
Remove all screws and fixtures of the existing roof hatch.
Take out the roof hatch.
See fig. 7
Remove the sealant around the opening using a scraper or similar tool.
See fig. 8
A
Seal the screw holes and recesses with a flexible non-hardening butyl
sealing compound (e.g. SikaLastomer-710).
8.4 Laying the connecting cables
D
The roof air conditioner must be connected to an electric circuit which is able
to supply the required current (see chapter “Technical data” on page 22).
Select the cross-section of the cable corresponding to the length:
Length < 7.5 m: 1.5 m
Length > 7.5 m: 2.5 m
See fig. 9
Make an opening on one side in order to feed through the electrical power
supply cable.
Feed the 230 Vw cable through the opening into the vehicle interior.
NOTE
Existing roof hatch openings in accordance with fig. 3 are
suitable for installing the roof air conditioner.
Dispose of all waste material, glue, silicone and seals sepa-
rately. Observe the disposal guidelines.
The manufacturer only assumes liability for parts included in
the scope of delivery. The validity of the warranty expires if the
device is installed together with third-party parts.
NOTICE!
Observe the sealant manufacturer’s instructions.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic FreshJet 2600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic FreshJet 2600 in the language / languages: All languages as an attachment in your email.

The manual is 6,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic FreshJet 2600

Dometic FreshJet 2600 User Manual - All languages - 512 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info