See also “General Troubleshooting” on page 14.
Low airflow. 1. Airflow is blocked. Remove any obstructions in return-air stream. Clean return-air
filter and grille. Check for crushed or restricted ducting; ducting must be as straight,
smooth and taut as possible.
2. Fan speed is set to Manual Low. If the fan speed is set to Manual Low, press and
release the Fan button until the desired fan speed and airflow are reached. If
automatic fan-speed control is desired, press and release the Fan button until the
indicator light next to the word AUTO is lit.
3. Fan Coil is iced. See below.
Fan coil is iced. 1. Thermostat set point is too low. Raise set point.
2. Improper airflow. Remove any obstructions in return air stream. Clean return air filter
and grille. Check for crushed or restricted ducting. Ducting must be as straight,
smooth and taut as possible. See the “Digital-Controls Troubleshooting” on page 15
for reprogramming options.
3. Supply air is short-cycling. Redirect supply air so that is not blowing into the return
air stream. Seal any air leaks on duct.
4. Humidity level too high. Close hatches and doors.
5. When all else fails. Switch air conditioning unit to heat until ice melts or use hair
dryer to melt.
Water coil is iced in the
Heating Mode.
Seawater temperature is below 40°F (4.4°C). Shut down system to prevent damage to
condenser. Allow coil to defrost.
System runs continuously. 1. Set point temperature is improperly set: too low for cooling or too high for
heating. Raise or lower set point.
2. Porthole or hatches open. Close all port holes and hatches.
3. Seawater temperature too high for cooling or too low for heating. Seawater
temperature will directly affect the air conditioning unit’s efficiency. This air
conditioning unit can effectively cool your boat in water temperatures up to 90°F
(32.2°C) and heat (if reverse cycle option is installed) in water as low as 40°F (4.4°C).
4. Improper air sensor location. Check your specific control troubleshooting section.
Table 4: Digital-Controls Troubleshooting
PROBLEM POSSIBLE REASON/SOLUTION
Digital display panel is not
lit.
The 8-pin display-cable plugs are not making contact (unplugged, dirty, bent, or
broken pins). With POWER OFF at the circuit breaker, remove connector and inspect. If
damaged, replace connector or entire display cable.
Fan is not running or runs
continuously.
Digital control is set for either fan cycling with compressor or continuous fan
operation. Press and hold the Fan button for five seconds to change the fan operation to
cycled (“CYC”) or continuous (“con”). Note: When configured for electric heat, after a heat
cycle ends the fan will stay on for 4 minutes even if the fan is set to cycled operation.
Fan is not running but the
compressor is.
Failed triac on circuit board. Send for repair or call local service technician.
Fan runs continuously
although it is set to cycle
with compressor.
Failed triac on circuit board. Send for repair or call local service technician.
Table 3: General Troubleshooting (continued)
PROBLEM POSSIBLE REASON/SOLUTION
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic Elite Control DX systems at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic Elite Control DX systems in the language / languages: English as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info