CoolAir RT780 Display messages
17
8.2 Control panel fault messages
The “Fault” LED (fig. 2 2, page 3) lights up if there is a fault with the parking cooler.
The type of error is shown on the display by the following error codes:
Display
text
Description Cause Remedy
FO1
The compressor does not
work.
Compressor overload or
fault in the electricity supply
to the compressor.
Switch off the system.
Switch it on again after
60 minutes.
If the fault occurs again,
contact an authorised
workshop.
Do not operate the system
at ambient temperatures
of below 0 °C or above
43 °C.
FO2
The system cannot
determine the current
temperature.
Room temperature sensor is
not correctly connected to
the parking cooler or the
measured value is not within
the specifications.
FO3
System overload, the
compressor switches off.
Thermal overload due to a
defective fan or an ambient
temperature that is too
high.
FO4
FO5
Overload due to fan. Short circuit in condenser
fan or evaporator fan.
Leave the system switched off
and consult an authorised
service centre.
FO6
Communication problem
between display unit and
control unit.
Fault in the wiring.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic COOLAIR RT 780 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic COOLAIR RT 780 in the language / languages: All languages as an attachment in your email.

The manual is 0,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dometic COOLAIR RT 780

Dometic COOLAIR RT 780 Installation Guide - All languages - 272 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info