CD20, CD30 Troubleshooting
15
Compressor does not run
Feature Possible cause Remedy
UTerm 0 Volt There is an interruption in the
connection between the battery and
the electronics
Establish a connection
Main switch faulty (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
UTerm UON Battery voltage is too low Charge the battery
During attempted start
up UTer m UOFF
Loose cable connection
Poor contact (corrosion)
Establish a connection
Cable cross section too small Replace the cable
(fig. 6, page 5)
Battery capacity too low Replace the battery
During attempted start
up UTer m UON
Ambient temperature too high
Insufficient ventilation and/or air
supply
Move the refrigerator to
another location
Condensor is dirty Clean the condenser
Electric circuit between
the pins in the
compressor interrupted
Defective compressor Replace the compressor
UTerm Voltage between the positive and negative electronic terminals
UON Switch on voltage of the electronic connection terminals
(see chapter “Technical description” on page 10)
UOFF Switch off voltage of the electronic connection terminals
(see chapter “Technical description” on page 10)
CD20-30-IO-16s.book Seite 15 Montag, 18. Mai 2020 2:25 14
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dometic CD30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dometic CD30 in the language / languages: All languages as an attachment in your email.

The manual is 4,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info