500152
15
Zoom out
Zoom in
Previous page
1/24
Next page
15
GB
5 Maintenance
5.3 Cleaning the hygienic exhaust filter
1. Switch off the appliance and pull the plug from the mains socket,
ZChapter 4.3, “Switching off”.
2. Slide the catch of the exhaust filter cover to the side (Fig. 12/A) and re-
move the exhaust filter cover.
3. Remove the hygienic exhaust filter by pulling the tab provided for this
purpose (Fig. 12/B).
4. If you discover that the hygienic exhaust filter is dirty, brush off the dirt
with a soft, dry brush, such as the furniture brush supplied.
5. If such dry cleaning is insufficient, rinse the filter by hand in running cold
or hand-warm water.
6. If the filter is damaged or deformed, replace it (ordering information
ZChapter 5.4, “Spare parts and accessories”).
7. Put the new / cleaned and completely dry exhaust filter back into its re-
ceptacle (Fig. 12/B).
8. Attach the exhaust filter cover at the backside first (Fig. 13/A).
9. Then push down the exhaust filter cover until you feel and hear it snap
into place. It might be easier if, while doing so, you move the lock slight-
ly to the side (Fig. 13/B).
5.4 Spare parts and accessories
Ordering address: ZPage 48, “International Service”
Further information is available at: Z www.dirtdevil.de
5.5 Recommendation
We recommend:
>> Swirl
£
Y293 dust filter bags with MicroPor
£
Filtration <<
Swirl
®
, MicroPor
®
and ‘Y293’ are registered trade marks of a company of the Melitta group and are used with their permission.
5.6 Before you send in the appliance
Before contacting your Royal service partner or appliance market and be-
fore sending in the appliance, first follow the procedure in the following ta-
ble to check if you can solve the problem yourself.
NOTE:
There is an imprint on the hygienic exhaust filter which should help you
to keep to the six-month interval between changes.
AB
12
A
B
13
ATTENTION:
The filters are washable, but not suitable for cleaning in washing
machines or dishwashers. Do not use cleaning agents for cleaning.
Leave the filters to dry after cleaning them with water (approx. 24 hours
at room temperature). Only put them back into the appliance when they
are completely dry.
ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have purchased by reordering.
Item number Description
3050022 Set of 5 dust filter bags and 1 motor protection filter
7120002 1 hygienic exhaust filter
M232 1 long, flexible crevice nozzle
M203 1 parquet brush
M209 1 turbo brush
NOTE:
Insert the dust filter bag in the ‘A’ direction.
WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing ZChapter 4.3, “Switching off”.
Problem Possible cause / solution
Filter bag
change indica-
tor (Fig. 1/5)
appears in the
display win-
dow
The dust filter bag is full. Change the dust filter bag,
ZChapter 5.1, “Changing the dust filter bag”.
Nozzle, telescopic tube or suction hose is blocked.
Remove the obstacle. If necessary, use a long wooden
stick (e.g. a broomstick) to do this.
The filters are dirty. Clean the respective filter ZChapter
5.2, “Cleaning the motor protection filter” or ZChapter
5.3, “Cleaning the hygienic exhaust filter”.
The vacuum
cleaner stops
suddenly.
The overheating protection has tripped (possibly due to
blocked suction channels, filters, or similar). Switch the
appliance off and pull the plug out of the socket. Remove
the cause of overheating (e.g. by disassembling tele-
scopic tube and suction hose and removing the obstacle
and/or cleaning filters). Wait for about 45 minutes. After
the appliance has cooled off, you may switch it on again.
The cleaning
results are un-
satisfactory in
spite of the ap-
pliance work-
ing correctly.
The bypass vent (Fig. 1/15) is open.
Close the bypass vent (Fig. 1/15).
The attached nozzle is unsuitable.
Change the nozzle, ZChapter 3.3, “Selecting and put-
ting on the nozzle”.
Position of the suction power control (Fig. 1/2) is not suit-
able for the floor.
Adjust the suction power control (Fig. 1/2), ZChapter
4.2, “Vacuum cleaning”, step 4.
Nozzle, telescopic tube or suction hose is blocked.
Remove the obstacle. If necessary, use a long wooden
stick (e.g. a broomstick) to do this.
When vacu-
uming with the
long, flexible
crevice nozzle,
there is sud-
denly a high-
pitched whis-
tling and the
suction power
drops consid-
erably.
The pressure in the vacuum cleaner became too low and
caused the safety valve to trigger.
Open the bypass vent until the valve no longer triggers.
Problem Possible cause / solution
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dirt Devil BG-2 Black label at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dirt Devil BG-2 Black label in the language / languages: English, German, French as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dirt Devil BG-2 Black label

Dirt Devil BG-2 Black label User Manual - Dutch, Italian, Turkish, Spanish - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info