Start-Up
When all mounting and connection work has been
completed, the functioning of the unit is to be tested.
The following minimum tests should be carried out:
- Insulation test with a voltage of at least 500 V.
- The insulation resistance must be at least 0.5 M
.
- Measure the power consumption of the device. If
necessary, cold resistance measurement may be carried
out.
Initial heating of units by a specialist is not necessary.
Reassembly
If devices which were already installed and operated are
dismantled and reassembled in another place, they, too,
must be started-up according to the above instructions after
installation. During installation please ensure that the
thermal insulation is not damaged. Damaged parts of the
thermal insulation must be replaced.
The initial charging after reassembly starting with the device
in cold state (room temperature) up to the switching off of the
charge controller must be monitored by a technician.
Measure the electrical energy (kWh) stored. It must not
exceed 125% of the rated charging stated on the power
rating plate.
Repair Notice
Electric storage heaters may only be repaired by qualified
personnel. Repairs which are improperly carried out can
endanger the safety of the user.
The devices have a high-grade thermal insulation. Only
remove the core room cover with integrated thermal
insulation when replcaing the heating elements. All other
electrical components can be accessed by removing the side
panels.
Resetting the Temperature Limiter
Note on Disposal
Do not dispose of the unit with general household
waste. The device must be taken to a local waste
disposal plant.
English Start-Up, Technical Device Information
Technical Device Information
*for max 6 h of charging
Designation Brick bundles Heating
element set
Nominal
power
Nominal
voltage
Nominal
charging
Weight Transport
weight
Dimensions
W x H x D
VFMi 20C 4 x 25
HFi 212
HFi 216
HFi 220
HFi 227*
1250 W
1600 W
2000 W
2700 W*
3/NPE
400V 50Hz
16 kWh 98 kg 34 kg
626 x 672 x 250
mm
VFMi 30C 6 x 25
HFi 318
HFi 324
HFi 330
HFi 340*
1850 W
2400 W
3000 W
4000 W*
3/NPE
400V 50Hz 24 kWh 137 kg 40 kg
776 x 672 x 250
mm
VFMi 40C 8 x 25
HFi 425
HFi 432
HFi 440
HFi 452*
2500 W
3200 W
4000 W
5200 W*
3/NPE
400V 50Hz 32 kWh 176 kg 46 kg
926 x 672 x 250
mm
VFMi 50C 10 x 25
HFi 540
HFi 550
HFi 564*
4000 W
5000 W
6400 W*
3/NPE
400V 50Hz 40 kWh 215 kg 52 kg
1076 x 672 x 250
mm
VFMi 60C 12 x 25
HFi 648
HFi 660
HFi 676*
4800 W
6000 W
7600 W*
3/NPE
400V 50Hz 48 kWh 254 kg 58 kg
1226 x 672 x 250
mm
VFMi 70C 14 x 25
HFi 756
HFi 770
HFi 790*
5600 W
7000 W
9000 W*
3/NPE
400V 50Hz 56 kWh 293 kg 64 kg
1376 x 672 x 250
mm
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex VFMi 20C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex VFMi 20C in the language / languages: English, German as an attachment in your email.

The manual is 2,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex VFMi 20C

Dimplex VFMi 20C Usermanual and installation guide - Dutch, French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info