798169
47
Zoom out
Zoom in
Previous page
1/52
Next page
www.dimplex.eu 2007/A EN-21
Commissioning English
P11 - auxiliary heating Yes/No
NOTE
The auxiliary heating is available as an accessory and
is not installed at the factory.
Enter whether operation is to take place with or with-
out auxiliary heating.
Call up the installer menu.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Use the   keys to select P11. Display flashes.
Press the ENTER key. ON flashes.
Operation with auxiliary heating:
Press the ENTER key. Setting is complete.
Operation without auxiliary heating:
Use the   keys to select OFF. OFF flashes.
Press the ENTER key. Setting is complete.
P12 - release signal
Function for future charge release directly on the stor-
age heater. Currently without function.
NOTE
This menu item may be shown or not shown depend-
ing on the version. Do not change the setting values!
P13 - release manual
NOTE
Only required if there is a continuous voltage on the
terminals L1, L2, L3 and no release takes place by the
energy supplier or grid operator.
Call up the installer menu.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Use the   keys to select P13. Display flashes.
Press the ENTER key. A1 flashes.
Press the ENTER key. The hours display flashes.
Use the   keys to set the hour for the start of
the release.
NOTE
When entering the release times, always start with the
lowest hour, e.g. 00:00.
Example:
The release times 22:00 to 06:00 and 14:00 to 16:00
should be set.
Set A1 ON to 00:00 and A1 OFF to 06:00.
Set A2 ON to 14:00 and A2 OFF to 16:00.
Set A3 ON to 22:00 and A2 OFF to 23:59.
A4 ON and A4 OFF remain on 23:59.
P14 - Failing charge control signal
If due to an error the signal of the central charge con-
trol fails the heater will be charged to maximum.
In order to change to no charging please proceed as
described below.
Call up the installer menu.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Use the   keys to select P14. Display flashes.
Press the ENTER key. ON flashes.
Use the   keys to select OFF. OFF flashes.
Press the ENTER key. Setting is complete.
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex VFE40K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex VFE40K in the language / languages: English, German as an attachment in your email.

The manual is 4.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info