798167
32
Zoom out
Zoom in
Previous page
1/52
Next page
EN-6 2007/A www.dimplex.eu
English Function of the storage heater
2. Function of the storage heater
General description
A storage heater stores the heat it needs for the next
day in its storage core, usually over night. This means
that electrical energy is saved at a time when the elec-
tricity distribution grids run by the energy suppliers
are not fully utilised.
In certain regions, the storage heater can be set so
that additional heat is stored at defined times of the
day. The majority of the energy is usually charged and
stored over night, however.
When the storage heater is in operation, cracking
noises can sometimes be heard. This is completely
normal and is due to temperature changes in the stor-
age core.
First heat up
As with all new devices, new materials in the heating
device can give off a slight odour in the first days of
operation.
Please ensure that there is sufficient ventilation.
Thermal storage
The quantity of thermal energy (charge) stored in the
heating device core is determined by the load control-
ler integrated in the device. The user has several op-
tions for operating the load controller:
Weather-dependent charging with central charge
control
Room-dependent charging
Manual charge reduction
Weather-dependent charging
For this, a central charge control device is fitted in the
distribution with outside temperature recording
(weather sensor).
In this configuration, the charge quantity is deter-
mined based on the user entries and the weather con-
ditions.
Manual charge reduction
This enables the user to adjust the charge quantity in
10% increments if no central charge control is pres-
ent.
In this configuration, the heating device charges the
percentage value set by the user as a maximum, re-
gardless of the weather and room conditions.
Room-dependent charging
If this mode is activated, the charge electronics calcu-
lates the charge quantity based on the room temper-
ature conditions to fulfil the heat consumption of the
user as effectively as possible.
Heat output
The room temperature control takes place via the
room temperature controller integrated in the heating
device as standard, but can also take place via a room
temperature controller mounted externally.
The room temperature controller is a separate item
which is not included in the scope of supply of the
product.
The desired configuration is set up by the installer.
The quantity of thermal energy output by the storage
heater is regulated automatically by the room temper-
ature controller. If the room temperature falls below
the set value, the room temperature controller
switches the fan of the storage heater on automati-
cally. The heating device also has other options. The
most important options are outlined briefly below:
Timer week program
Time-dependent specification of comfort and energy
saving mode. The desired room temperature can be
set in comfort mode. In energy saving mode, the room
temperature set for comfort mode is lowered auto-
matically.
Auxiliary heating (optional)
If the stored charge is not sufficient to heat the room
up to the desired temperature, the AUXILIARY HEAT-
ING function provides additional heat.
NOTE
This function can only be used in conjunction with the
AUXILIARY HEATING accessory.
Open window detection
The room heating device is equipped with a monitor-
ing function that detects whether unnecessary en-
ergy is being consumed due to an open window. In
this case, the heating device reduces the heat output.
Adaptive startup
This function guarantees that the set room tempera-
ture is achieved exactly at the start of comfort mode.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex VFE20K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex VFE20K in the language / languages: English, German as an attachment in your email.

The manual is 4.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info