798174
15
Zoom out
Zoom in
Previous page
1/48
Next page
www.dimplex.de/en 1810/B EN-3
TRP 100 M, TRP 100 W English
3. Electrical connection
The voltage specified on the type plate must match the
line voltage.
The cable must not be in contact with the casing.
It is recommended that a separate circuit be provided
for the power supply.
The device must only be installed and repaired by a
qualified electrician in accordance with the applicable
safety regulations. Heating device must be earthed!
Connection may only take place on securely routed
cables!
A disconnecting device with a contact opening of at
least 3 mm at each pole (e.g. circuit breaker) must be
provided in the permanently installed wiring.
4. Overload protector
For your safety, the heating device is equipped with an
overload protector. If the air circulation is interrupted
(e.g. due to the air grille being covered or closed), the
device switches off automatically.
In this case, the power supply to the heating device
should be disconnected for a few minutes (disconnect
the plug, switch off the fuse) to allow the device to cool
down sufficiently.
Before recommissioning the device, remove the
reasons for the overload protector being triggered.
5. Cleaning
The device must be disconnected from the mains and
allowed to cool down before cleaning and
maintenance. Clean the outside of the device using a
soft, damp cloth. Do not use scouring powder or
furniture polish as this may damage the surface. Dust
which gathers inside the device can be removed from
the outside using a vacuum cleaner.
6. Faults
If Err appears on the display, there is a fault.
Deleting the error message
Press and hold the ENTER key for ten seconds.
Err disappears.
Device is ready for operation again.
244244
375800
Display Meaning Measures
Err1 Temperature sen-
sor faulty.
Notify the factory
after-sales service.
Err2 Window monitor-
ing triggered.
Close window.
Delete error message.
Deactivate the function
where applicable,
see chapter 11.6
Err3 Heating device
overheated.
See chapter 4.
Delete error message.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex TRP100W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex TRP100W in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info