520436
7
Zoom out
Zoom in
Previous page
1/32
Next page
- 3 -
Operation with air/water heat pumps
When operating with an air/water heat pump, particularly when
temperatures are low outside, the heat pump's buffer tank
must be at a temperature of at least 1C to ensure that the
heat pump evaporator can defrost. You should therefore en-
sure that thawing has taken place if necessary before opening
the valves to the heating circuit.
Troubleshooting
The following causes can result in the fan convector producing
insufficient heat:
Red indicator flashes:
See "Fault indication" section
Air trapped in heat exchanger:
Disconnect device from power supply, remove casing and
bleed heat exchanger. For position of bleeder screw, see fig.
4.
Water temperature too low:
Set flow temperature higher on heating system.
Insufficient water flow rate through device:
Adjust flow rate (hydraulic balance). To do this, close ther-
mostat valves on the other heaters.
Dirt on heat exchanger:
Clean heat exchanger, see "Maintenance" section.
Cleaning outer surfaces
The heater must be switched off and cooled for cleaning. The
surfaces of the heater can be cleaned by wiping with a soft,
damp cloth and then dried. Do not use abrasive powder or fur-
niture polish to clean as these may damage the surface.
Maintenance – to be performed by a specialist
Dust or lint that collects inside the heater must be removed at
regular intervals.
To do this, disconnect the device from the power supply, loosen
the 4 fixing screws on the underside of the casing and carefully
remove the casing cover. Remove dirt with a soft brush or a
vacuum cleaner.
Build-up of air in the heat exchanger can be remedied by open-
ing the bleeder valve (fig. 4).
Warranty
We offer a two-year warranty for this device in accordance with
our warranty conditions.
Glen Dimplex Deutschland GmbH Phone +49 9221 709564
Am Goldenen Feld 18 Fax +49 9221 709589
D-95326 Kulmbach www.glendimplex.de
Subject to modifications EN 01/11/C
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex SRX 180M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex SRX 180M in the language / languages: English, German, Dutch, Danish, French, Polish, Norwegian, Finnish as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info