798307
71
Zoom out
Zoom in
Previous page
1/76
Next page
www.gdts.one 452236.66.09 · FD 9912 A-XIII
SIW 6TES - SIW 11TES Anhang · Appendix · Annexes
R9 Vorlauffühler Heizkreis Flow sensor for heating circuit Sonde départ circuit de chauffage
R24 Rücklauffühler Primärkreis Return sensor, primary circuit Sonde retour circuit primaire
T1 Sicherheitstransformator 230 / 24 V AC - Rege-
lung
Safety transformer 230 / 24 V AC - Regulation Transformateur de sécurité 230 / 24 V AC - Régu-
latio
X1 Klemmleiste Einspeisung Last Terminal strip infeed load Alimentation bornier charge
X1.1 Stecker Lastspannung Plug supply voltage Connecteur tension de puissance
X2 Klemmleiste Spannung = 230 V AC Schaltkasten Terminal strip voltage = 230 V AC Tension bornier = 230 V AC
X3 Klemmleiste Kleinspannung < 25 V AC
Schaltkasten
Terminal strip extra-low voltage
< 25 V AC Switch box
Faible tension bornier
< 25 V AC Boîtier électrique
X7 Klemmleiste Leistungsanpassung E10.1 Terminal strip output adjustment E10.1 Bornier adaptation de puissance E10.1
X12 Stecker Steuerspannung 230 V Plug control voltage 230 V Connecteur tension de commande 230 V
X13 Stecker Kleinspannung <25 V Plug extra-low voltage <25 V Connecteur faible tension < 25 V
XM11.1 Stecker Primärkreispumpe Last Connector primary circuit pump load Connecteur pompe circuit primaire charge
XM11.2 Stecker Primärkeispumpe Steuerung Connector primary circuit pump control Connecteur pompe circuit primaire commande
KM13.1 Stecker Heizungsumwälzpumpe Last Connector heat circulating pump load Connecteur circulateur du circuit de chauffage
charge
KM13.2 Stecker Heizungsumwälzpumpe Steuerung Connector heat circulating pump control Connecteur circulateur du circuit de chauffage
commande
XM18.1 Stecker Warmwasserladepumpe Last Connector domestic hot water circulating pump
load
Connecteur pompe de charge d'eau chaude sani-
taire charge
*Bauteile sind bauseits anzuschließen / beizustel-
len
Components must be connected / supplied by the
customer.
Les pièces sont à raccorder / à fournir par le client
[] Flexible Beschaltung - siehe Vorkonfiguration
(Änderung nur durch Kundendienst)
Flexible circuitry - see pre-configuration (changes
by after-sales service)
Commande flexible - voir pré-configuration (modi-
fication uniquement par le SAV)
____ werkseitig verdrahtet Wired ready for use blé en usine
------ bauseits nach Bedarf anzuschliessen to be connected on site if required à raccorder par le client si besoin
ACHTUNG!
!!
An den Steckklemmen N1-J1 bis J11, -24 bis
J26 und der Klemmleiste X3 liegt
Kleinspannung an. Auf keinen Fall darf hier
eine höhere Spannung angelegt werden.
ATTENTION!
!
!
Extra-low voltage is supplied to plug-in
terminals N1-J1 to J11, J23 to J26 and the
terminal strip X3. Higher voltage must not be
supplied here under any circumstances.
ATTENTION !
!!
Une faible tension est appliquée aux bornes
enfichables N1-J1 à J11, J23 à J26 des bornier
X3. Ne jamais appliquer une tension plus
élevée.
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex SIW 11TES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex SIW 11TES in the language / languages: English, German, French as an attachment in your email.

The manual is 2.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info