798473
17
Zoom out
Zoom in
Previous page
1/48
Next page
www.dimplex.de E-7
English
12
12 Device Information
Device information for brine-to-water heat pumps for heating purposes
1 Type and order code SI 5CS SI 7CS SI 9CS SI 11CS SI 14CS SI 17CS SI 21CS
2Design
2.1 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 IP20 IP20 IP20
2.2 Installation Location Indoors Indoors Indoors Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 55 Up to 55 Up to 55 Up to 55 Up to 55 Up to 55 Up to 55
Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25
Antifreeze Mono-
ethylene
glycol
Mono-
ethylene
glycol
Mono-
ethylene
glycol
Mono-
ethylene
glycol
Mono-
ethylene
glycol
Mono-
ethylene
glycol
Mono-
ethylene
glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25% 25% 25% 25%
3.2 Temperature spread of heating water (flow/return flow)
at B0 / W35 K 10.1 9.9 10.5 10.1 9.6 9.3 11.3
3.3 Heat output / COP at B-5 / W55 1kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
3.8 / 1.96 5.6 / 2.2 7.7 / 2.3 9.4 / 2.4 12.5 / 2.6 14.4 / 2.6 17.9 / 2.5
at B0 / W50 1kW / --- 4.8 / 2.75 6.7 / 2.9 9.0 / 3.1 11.3 / 3.0 14.2 / 3.4 16.7 / 3.2 20.4 / 3.1
at B0 / W35 1kW / --- 5.3 / 4.3 6.9 / 4.3 9.2 / 4.4 11.8 / 4.4 14.5 / 4.5 17.1 / 4.6 21.1 / 4.3
3.4 Sound power level dB(A) 54 55 56 56 56 58 59
3.5 Heating water flow with an internal pressure differential of m³/h / Pa 0.45 /
2000
0.6 /
2500
0.75 /
4500
1.0 /
3500
1.3 /
3500
1.5 /
4000
1.6 /
6000
3.6 Brine throughput with an internal pressure
differential (heat source) of m³/h / Pa
1.2 /
6500
1.7 /
10000
2.3 /
16000
3.0 /
13000
3.5 /
13000
3.8 /
9000
6.0 /
12000
3.7 Refrigerant; total filling weight type / kg R407C /
1.7
R407C /
1.5
R407C /
1.8
R407C /
2.0
R407C /
2.3
R407C /
2.8
R407C /
4.5
4 Dimensions, connections and weight
4.1 Device dimensions without connections 2H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
800 ×
600 × 500
800 ×
600 × 500
800 ×
600 × 500
800 ×
600 × 500
800 ×
600 × 500
1380 ×
600 × 500
1380 ×
600 × 500
4.2 Device connections to heating system Inch G 1"
internal/
external
G 1"
internal/
external
G 1"
internal/
external
G 1"
internal/
external
G 1"
internal/
external
G 1¼''
internal /
G 1''
G 1¼''
internal /
G 1''
4.3 Device connections to heat source Inch G 1¼"
internal/
external
G 1¼"
internal/
external
G 1¼"
internal/
external
G 1¼"
internal/
external
G 1¼"
internal/
external
G 1½"
internal/
external
G 1½"
internal/
external
4.4 Weight of the transportable unit(s) incl. packing kg 131 133 134 145 157 165 215
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 16 400 / 16 400 / 16 400 / 16 400 / 16 400 / 20
5.2 Nominal power consumption 1 B0 W35 kW 1.23 1.6 2.07 2.66 3.22 3.72 4.91
5.3 Starting current with soft starter A 22 (with-
out SS)
30 (with-
out SS) 15 26 26 27 29
5.4 Nominal current B0 W35 / cos ϕA / --- 2.22 2.89 3.77 4.84 5.81 6.35 8.86
6 Complies with the European safety regulations 3
3. See CE declaration of conformity
333333
7 Additional model features
7.1 Water in device protected against freezing 4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes Yes Yes Yes Yes Yes Yes
7.2 Performance levels 1111111
7.3 Controller internal/external Internal Internal Internal Internal Internal Internal Internal
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex SI 14CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex SI 14CS in the language / languages: English, German, French as an attachment in your email.

The manual is 5.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info