EN-10 452235.66.22a · FD 0106 www.glendimplex.de
English SI 6TU - SI 18TU
12 Device Information
1 Type and order code SI 6TU SI 8TU SI 11TU
2 Design
2.1 Model Universal Universal Universal
2.2 controller Intern Intern Intern
2.3 Thermal energy metering Integreated Integreated Integreated
2.4 Installation location / degree of protection according to EN 60 529 Indoors / IP 21 Indoors / IP 21 Indoors / IP 21
2.5 Performance levels 111
3 Operating limits
3.1 Heating water flow 1°C
1. If necessary, the operating range can be extended to a brine inlet temperature of -10 °C. In this case, the minimum brine concentration must be adjusted to 30%. (Freezing
temperature -17 C°). At brine inlet temperatures of -10 °C to -5 °C, flow temperature rising from 55 °C to 62 °C.
20 to 62 ± 20 to 62 ±2 20 to 62 ±2
3.2 Brine (heat source) °C
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)1
-51 to +252
Monoethyleneglycol
25 %1
2. Operation is possible at brine inlet temperatures of up to + 35 °C. At brine inlet temperatures of +25 °C to +35 °C, flow temperature falling from 62 °C to 55 °C.
4 Performance data / flow rate 3
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
controller should be taken into consideration. The specified values have the following meaning, e.g. B0/W35: Heat source temperature 0 °C and heating water flow temperature
55 °C. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-up and operation can be found in the respective sections of
the installation and operating instructions.
4.1 Heating water flow rate at internal pressure differential
max. (EN14511) m³/h / Pa
minimal m³/h / Pa
1.05 / 5300
0.55 / 1500
1.4 / 7700
0.7 / 1900
1.9 / 10500
0.9 / 2400
4.2 Heat output / COP EN 14511 EN 14511 EN 14511
at B-5 / W45 kW / --- 5.0 / 3.1 6.5 / 3.2 9.1 / 3.2
at B0 / W55 kW / --- 5.5 / 2.8 7.2 / 2.8 10.0 / 2.9
at B0 / W45 kW / --- 5.8 / 3.6 7.5 / 3,6 10.4 / 3.7
at B0 / W35 kW / --- 6.1 / 4.7 8.1 / 4.8 10.9 / 4.9
4.3 Sound power level to EN 12102 4dB(A) 46 46 47
4.4 Sound pressure level at a distance of 1 m 4 5dB(A)
4. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3db (A).
5. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C. The specified sound pressure
level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
34 34 35
4.5 Brine flow with internal pressure differential heat source m³/h / Pa 1.45 / 8700 1.9 / 11000 2.6 / 14000
5 Dimensions, connections and weight
5.1 Device dimensions without connections6H x W x L cm
6. Note that additional space is required for pipe connections, operation and maintenance.
840 x 650 x 555 840 x 650 x 555 840 x 650 x 555
5.2 Device connections for heating system Inches G 1 1/4“ AG7
7. Flat-sealing
5.3 Device connections for heat source Inches G 1 1/4“ AG7
5.4 Weight of the transportable unit(s) incl. packaging kg 119 128 134
5.5 Refrigerant; total filling weight type / kg R410A / 2.5 R410A / 2.9 R410A / 3.3
5.6 GWP value / CO2 equivalent --- / t 2088 / 5 2088 / 6 2088 / 7
5.7 Refrigeration circuit hermetically sealed yes yes yes
5.8 Lubricant; total filling quantity type / litres Polyolester
(POE) / 0.7
Polyolester
(POE) / 1.2
Polyolester
(POE) / 1.2
6 Electrical connection
6.1 Supply voltage / fuse protection V / A 3~ / PE 400V (50Hz) / C10A
6.2 Control voltage / fuse protection V / A 1~ / N / PE 230V (50Hz) / C13A
6.3 Nominal power consumption
B0 / W35 / max. power consumption 3kW 1.30 / 2.6 1.67 / 3.2 2.22 / 4.3
6.4 Starting current with soft starter A 28 (without
soft starter) 17 20
6.5 Nominal current B0 / W35 / cos A / --- 2.35 / 0.8 3.01 / 0.8 4.01 / 0.8
7 Complies with the European safety regulations 8
8. See CE declaration of conformity
8 8
8 Additional model features
8.1 Heating water in device protected against freezing9
9. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes Yes Yes
8.2 Max. operating overpressure (heat source/heat sink) bar 3.0 3.0 3.0
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex SI 11TU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex SI 11TU in the language / languages: English, German, French as an attachment in your email.

The manual is 2.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex SI 11TU

Dimplex SI 11TU Usermanual and installation guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info