SI 10MER Anhang · Appendix · Annexes
R6 Vorlauffühler Primärkreis Flow sensor for primary circuit Sonde aller circuit primaire
R7 Codierwiderstand 19k6 Coding resistor 19.6 kOhm Résistance de codage 19k6
R8 Frostschutzfühler Kühlen Flow sensor, cooling Sonde antigel refroidissement
R9 Vorlauffühler Heizkreis Flow sensor for heating circuit Sonde aller circuit de chauffage
R13* Fühler regenerativ, Raumfühler,
Fühler 3. Heizkreis
Renewable sensor, room sensor,
sensor for heating circuit 3
Sonde mode régénératif, sonde d'ambiance, sonde
3ème circuit de chauffage
R20* Schwimmbadfühler Swimming pool sensor Sonde de piscine
T1 Sicherheitstransformator 230 / 24 V AC Safety isolating transformer 230 / 24 V AC Transformateur sectionn. sécu. 230 / 24 V AC
T2 Sicherheitstransformator 230 /24 V AC Safety isolating transformer 230 / 24 V AC Transformateur sectionn. sécu. 230 / 24 V AC
X1 Klemmleiste Einspeisung Terminal strip, infeed Alimentation bornier
X2 Klemmleiste Spannung = 230 V AC Terminal strip voltage = 230 V AC Tension bornier = 230 V AC
X3 Klemmleiste Kleinspannung < 25 V AC Terminal strip, extra-low voltage < 25 V AC Faible tension bornier < 25 V AC
X4 Klemmleiste Verdichter Terminal strip compressor Compresseur bornier
X5 Busverteilerklemme Bus distribution board terminal Réglettes Bus
Y1 Vier-Wege-Ventil Four-way valve Vanne d’inversion 4 voies
Y12* externes 4-Wege-Ventil
(Heizkreisumkehrung)
External 4-way reversing valve
(heating circuit
Vanne d'inversion 4 voies externe
(inversion circuit
*Bauteile sind bauseits anzuschließen /
beizustellen
Components must be connected / supplied by
the customer
Les pièces sont à raccorder / à fournir par le client
[ ] Flexible Beschaltung - siehe Vorkonfiguration
(Änderung nur durch Kundendienst!)
Flexible switching - see pre-configuration
(changes by after-sales service only!)
Commande flexible - voir pré-configuration
(modification uniquement par le SAV !)
- - - - - bauseits bei Bedarf anzuschließen To be connected by the customer as required à raccorder par le client au besoin
––––– werksseitig verdrahtet Wired ready for use câblé départ usine
ACHTUNG!
!
!
An den Steckklemmen N1-J1 bis J11, J25,
j26, N17-J1 bis J4, -J9, -J10 und der
Klemmleiste X3 liegt Kleinspannung an. Auf
keinen Fall darf hier eine höhere Spannung
angelegt werden.
ATTENTION!
!!
Plug-in terminals N1-J1 to J11, J25, J26,
N17-J1 to J4, -J9, -J10 and terminal strip X3
are connected to extra-low voltage. A higher
voltage must on no account be connected.
ATTENTION !
!
!
Une faible tension est appliquée aux bornes
enfichables N1-J1 à J11, J25, J26, aux bornes N17-
J1 à J4, -J9, -J10 et au bornier X3. Ne jamais
appliquer une tension plus élevée.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex SI 10MER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex SI 10MER in the language / languages: English, German, French as an attachment in your email.

The manual is 2.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info