Fitting Product - see Fig. 4 - 11
There are three possible mounting meathods
1. Surface Mounting
2. Partial Recessed (Not on 74" Models)
3. Flush Mount
Surface Mounting (34" & 74" Models)- see
Fig. 4 & 5
CAUTION: Two people will be required for various steps
of this procedure.
WARNING: Ensure that the circuit on which the replace
is to be installed has the power cut off at the service panel
until installation is complete.
1. Determine the mounting location of the unit so that
the wall-mounting bracket can be installed into a
minimum of 2 wall studs for the 34" Models and 4 wall
studs for the 74" Models
!
NOTE: It is recommended that the mounting bracket
be installed 56 in. (142 cm) off of the ground to maintain an
optimized viewing angle of the ame.
2. Hold the wall mounting bracket, with the bubble level
on the top, on the wall so that the bubble on the level
is centered between the two black lines.
3. Mark the 4 mounting screw locations, on the wall,
ensuring that the wall bracket stays level (Fig. 4)
marked (A).
4. In locations where the screws are being installed only
into drywall, install the supplied wall anchors before
installing the screw (predrill if required).
5. Secure the wall bracket to the wall using the supplied
1 ½ in. (3.8 cm) mounting screws and washers into the
wall and/or wall anchors.
6. Install the bottom support bracket to the wall centered
with the wall mounting bracket, using the appropriate
mounting hardware, 13 ¾" (350 mm) below the wall
mounting bracket (Fig. 4) marked (B).
7. Remove the center screw from the bottom of the
replace. (Fig. 5)
8. Hang the replace from the bracket.
9. Install the previously removed screw through the
bottom support bracket into the replace.
10. Refer to Front Glass Installation section for nal
installation procedures.
Surface Mounting (50" Models) - see Fig. 6 & 7
CAUTION: Two people may be required for various
steps of this procedure.
1. Choose a location which has a minimum of two wall
studs available for mounting.
2. Choose your method of supplying power to the unit:
Plug in to an existing outlet or install an outlet nearby.
Hard wire the replace.
WARNING: Do not attempt to wire your own new outlets
or circuits. To reduce the risk of re, electric shock or injury
to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the replace
is to be installed has the power cut off at the service panel
until installation is complete.
3. Remove the partially reective glass from the replace:
Lay replace on its back.
Remove two Phillips screws from each of the two glass
brackets (Fig. 6) marked (A).
Remove glass brackets (Fig. 6) marked (B).
With one hand keeping pressure on the partially
reective glass, tilt the replace upright and slightly
forward to allow the partially reective glass to fall out
of the inside framing.
CAUTION: Partially reective glass is not tempered. Do
not bump or drop the partially reective glass to avoid
breakage and personal injury.
Remove partially reective glass from replace.
4. Position the replace on a wall in the position where
it will be mounted (Fig. 7). Use a bubble level (one is
supplied) to ensure that replace is level on the wall.
5. Ensuring that at least two key-holes line up with a wall
stud (key-holes are spaced at 4 in. (10.2 cm) centers)
(Fig. 7) marked (A), mark the location of four screw
locations on the wall (through key-holes).
6. Remove fireplace from wall and store in a safe place
away from traffic.
7. Where marked screw locations do not line up with a
wall stud, insert (screw in) one of the two supplied wall
anchors (predrill if required). Repeat if only two screws
line up with a wall stud.
8. Screw all four supplied #8, 1 ½ in. (3.8 cm) square head
mounting screws and washers into the wall and/or wall
anchors leaving ¼ in. (6.5 mm) of thread.
9. Align chosen key-holes with screws and hang replace
on the wall. Screw heads and washers will t through
key-holes and replace will slide down into place
(screws will slide into narrow part of key-holes).
10. Tighten all four mounting screws down on replace
chassis.
11. Screw the two supplied #8 square head screws through
two of the permanent mounting holes (Fig. 7) marked
(C) which align with a wall stud.
12. Carefully replace and install partially reflective glass
and glass brackets using screws from step 1.
13. Refer to Front Glass Installation section for nal
installation procedures.
Partial Recessed (Not possible on 74" Models)-
see Fig. 8 & 9
CAUTION: Two people may be required for various
steps of this procedure.
1. Prepare a wall with a framed opening for the correct
model (Fig. 8)
34" Models: 30 ½ in. (77.5 cm) wide x 16 ½ in. (42 cm)
high
50" Models: 46 ½ in. (118.1 cm) wide x 16 ½ in.
(42 cm) high
!
NOTE: The sizing has allowed for ¼ in. (6.4 mm) around
the replace insert for ease of installation. This replace
does not require any additional venting.
2. Choose your method of supplying power to the unit:
Plug in (you may run the power cord out of the framed
wall opening to an existing outlet or install an outlet on
a nearby wall stud within the wall).
Hard wire the replace.
WARNING: Do not attempt to wire your own new outlets
or circuits. To reduce the risk of re, electric shock or injury
to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the replace
is to be installed has the power cut off at the service panel
until installation is complete.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex Prism 74 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex Prism 74 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish, Norwegian as an attachment in your email.

The manual is 9,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info