10.6 Minimum room temperature
This function can be used to ensure that a minimum
room temperature is specified even during OFF times,
for example in timer mode (week program).
NOTE
NOTE
The specification also applies for the runback timer
function. Frost protection mode has priority.
Press and hold the MENU key and the FORWARD
key for five seconds. rb display flashes.
Press the
key The display Sb flashes.
Press the ENTER key. The ON symbol flashes.
Press the ENTER key. The minimum room
temperature (factory setting 16° C) flashes.
Use
or
to set the minimum room temperature
and confirm with ENTER.
Confirm the BACK key to return to the standard
display.
10.7 Adaptive start-up
This function guarantees that the set room temperature
is reached precisely at the start of the switch-on time,
e.g. in conjunction with a time program.
Example:
In the timer menu, a set room temperature of 22°C is
specified. The current room temperature is 17° C. The
heating device switches on early so that the specified
room temperature of 22° C is reached by 07:00.
Press and hold the MENU key and the FORWARD
key for five seconds.
rb display flashes.
Press
or
to select the ADAPTIVE START
symbol. The symbol flashes.
Press the ENTER key.
Press
or
to select ON or OFF to switch the
function on or off.
Confirm the BACK key to return to the standard
display.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex PLX 200E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex PLX 200E in the language / languages: English, German, French, Italian, Polish as an attachment in your email.

The manual is 1.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex PLX 200E

Dimplex PLX 200E Usermanual and installation guide - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info