798053
2
Zoom out
Zoom in
Previous page
1/12
Next page
93mm
305mm
Energy Related Product Directive
Type of heat output/ room temperature control
With electronic room temperature control Yes
Electronic room temperature control plus week
timer Yes
With open window detection Yes
Model Identifier(s):
B075E C100E D150E E200E
Nominal heat
output Pnom 0.75 kW 1 kW 1.25 kW 1.5 kW
Height (mm)
659 659 659 659
Width (mm)
570 840 1105 1373
Depth (mm)
50 50 50 50
Minimum heat
output (indicative) Pmin 0.75 kW 1.00 kW 1.25 kW 1.5 kW
Maximum continu-
ous heat output Pmax,c 0.75 kW 1.00 kW 1.25 kW 1.5 kW
Auxiliary electricity Consumption
At nominal heat
output elmax 0.00 0.00 0.00 0.00
At minimum heat
output elmin 0.00 0.00 0.00 0.00
In standby mode elSB <0.0005 <0.0005 <0.0005 <0.0005
With open window detection Yes
This product complies with Lot20 of the Energy Eciency Directive (2015/1188)
General Information
Please read the instructions closely before first using the product.
The necessary wall mounting brackets are provided with the product as a
standard.
It should only be operated when in the upright position as shown - see Fig.1.
All models are IP20 rated. Before connecting the heater check that the supply
voltage is the same as that stated on the heater.
For further information on heater guards, please contact our guard supplier
direct on Tel. No. 020 7987 1184 or visit www.aianos.co.uk, or in case of diculty
or for further advice contact the Customer Helpline.
Wall Mounting
IMPORTANT - The radiator must only be mounted using the kit supplied
WARNING - This product is heavy and care should be taken in installation
Select a suitable position on a wall, near to a mains power outlet. The radiator
should not be mounted closer than 75mm from the floor - see Fig. 2 (to enable
cleaning), or adjacent side walls. Ensure at least 305mm clear space between
the radiator and any overhanging shelf. It should not be mounted closer than 1
metre from the ceiling.
STEP 1: Check that you have all the necessary components:
(a) 2 x Bottom wall brackets
(b) 2 x Top wall brackets
(c) 2 x Radiator securing brackets
(d) 2 x Self-tapping screws.
STEP 2: Using a straight edge, draw a horizontal line (see ‘Y’ in Fig. 2) for the
bottom brackets at the required mounting height from the floor.
75mm
(min)
‘C’
‘Y’
75mm
(min)
Fig. 2
Fig. 3
Fig. 4 Fig. 5
Electrical Connection
Place the bottom brackets centrally over these centres with the top row of holes
on the line, and mark the fixing hole positions – see Fig. 2.
STEP 3: Drill the holes and fit wall plugs. Screw the bottom brackets in position
– see Fig. 2.
STEP 4: Measure dimension D in Fig. 1 according to model, from the top of the
bottom brackets and draw a horizontal line. Mark o the fixing centres for the
top brackets in line with the bottom brackets. Place each top bracket on the
line and mark the fixing holes – see Fig. 3. Drill and plug the wall and fix the
top brackets in place.
STEP 5: Place the radiator on the bottom brackets, then fit each securing
bracket to the top of the radiator and secure it with the self-tapping screw
provided – see Fig. 4.
Check that the radiator is securely fixed to the wall.
This guide is for quick reference only
To view the full manual, please visit - www.dimplex.nl
NOTE - The bottom of the radiator must not be less than 75mm from the
floor. To achieve this the top edge of the bottom brackets must be at least
160mm from the floor - see Fig 2. On this line, mark o the fixing centres
according to model - see `C’ in the table in Fig. 1 and Fig. 2
IMPORTANT - For safe clearances from shelf/obstacle - see Fig. 5
(max)
(min)
The electrical installation must be carried out by a competent electrician,
and be in strictaccordance with the current I.E.E. Regulations for Electrical
Equipment in Buildings. The wires in this mains lead are coloured in accordance
with the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
The heater is fitted with a length of flexible cable type H05VV-F size 3 x
1.0mm2 for connection to the fixed wiring of the premises through a suitable
connection box positioned adjacent to the heater.
A means for disconnection must be incorporated in the fixed wiring of the
premises in accordance with the wiring rules. The supply circuit to the heater
must incorporate a double pole isolating switch having a contact separation
of at least 3mm.
WARNING - THIS APPLIANCE MUST BE EARTHED
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex MK1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex MK1 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info