520415
28
Zoom out
Zoom in
Previous page
1/60
Next page
EN-12
English
12
12 Device Information
1 Type and order code LIK 8TE
2Design
2.1 Model Compact
2.2 Degree of protection according to EN 60 529 for compact devices
and heating components IP 20
2.3 Installation location Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow/return flow °C / °C Up to 58 / above 18
Air °C -25 to +35
3.2 Temperature spread of heating water (flow/return flow) at A7 / W35 10.0 5.0
3.3 Heat output / COP at A-7 / W35 1kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C
and heating water flow temperature 55 °C.
5.8 / 2.7 5.5 / 2.6
at A-7 / W45 1kW / --- 5.4 / 2.1
at A2 / W35 1kW / --- 7.5 / 3.3 7.4 / 3.2
at A7 / W35 1kW / --- 9.3 / 3.9 9.2 / 3.8
at A7 / W45 1kW / --- 8.8 / 3.2
at A10 / W35 1kW / --- 9.8 / 4.1 9.7 / 4.0
3.4 Sound power level device / outdoors dB(A) 53 / 60
3.5 Sound pressure level at a distance of 1 m (indoors) dB(A) 48.0
3.6 Heating water flow
with an internal pressure differential of 2m³/h / Pa
2. The heat circulating pump is integrated.
0.8 / 2700 1.6 / 11900
3.7 Free pressure, heating circulating pump (max. stage) Pa 45000.0
3.8 Air flow rate
with an external static pressure differential of m³/h / Pa 2500 / 20
3.9 Refrigerant; total filling weight type / kg R404A / 2.0
3.10 Lubricant; total filling weight type / litres Polyolester (POE) / 1.5
3.11 Output of electric heating element
(second heat generator) kW 2.0
4 Dimensions, connections and weight
4.1 Device dimensions H x W x L cm 190 x 75 x 68
4.2 Device connections to heating system Inch G 1'' external
4.3 Air duct inlet and outlet (min. internal dimensions) L x W cm 44 x 44
4.4 Weight of the transportable unit(s) incl. packing kg 264
4.5 Buffer tank volume l 50
4.6 Buffer tank pressure rating bar 6
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 400 / 25
5.2 Nominal power consumption 1 A2 W35 kW 2.27 2.33
5.3 Starting current with soft starter A 19.5
5.4 Nominal current A2 W35 / cos ϕA / --- 4.1 / 0.8 4.2 / 0.8
6 Complies with the European safety regulations 3
3. See CE declaration of conformity
7 Additional model features
7.1 Defrosting Automatic
Type of defrosting Reverse cycle
Defrosting tray included Yes (heated)
7.2 Heating water in device protected against freezing 4
4. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes
7.3 Performance levels 1
7.4 Controller internal/external Internal
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LIK 8TE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LIK 8TE in the language / languages: English, German, French as an attachment in your email.

The manual is 1.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex LIK 8TE

Dimplex LIK 8TE Usermanual and installation guide - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info