www.glendimplex.de 452169.66.06 · FD 0009 EN-17
LI 16I-TUR English
8 Complies with the European safety regulations 8
9 Additional model features
9.1 Type of defrosting Reverse cycle
9.2 Condensate tray frost protection / Water in device is protected from freezing 9Yes
9.3 Max. operating overpressure (heat sink) bar 3.0
10 Heat output / COP 2
10.1 Heat output / COP EN 14511
with A-7 / W35 kW / --- 10.7 / 3.1
with A2 / W35 kW / --- 6.0 / 4.2
with A7 / W35 kW / --- 7.1 / 5.1
11 Cooling capacity / coefficient of performance (COP) 2 3
11.1 Cooling capacity / coefficient of performance (COP) EN 14511
with A27 / W18 kW / --- 8.6 / 3.9
with A27 / W7 kW / --- 8.0 / 3.0
with A35 / W18 kW / --- 9.8 / 3.6
with A35 / W7 kW / --- 7.1 / 2.4
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45°C to 60°C.
2. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found
in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A2/W35: Heat source temperature 2 °C and heating
water flow temperature 35 °C.
3. The maximum sound power level under full load can increase by up to 5 dB(A).
4. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 db(A).
5. The heat output and COP is reduced by approx. 5% in lower operation
6. The specified sound pressure level represents the free sound area level. The measured value can vary by up to 16 dB(A), depending on the installation location.
7. Note that additional space is required for pipe connections, operation and maintenance.
8. see CE declaration of conformity
9. The heat circulating pump and the heat pump manager must always be ready for operation.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LI 16I-TUR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LI 16I-TUR in the language / languages: English, German, French as an attachment in your email.

The manual is 4.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info